IMPORTANT NOTE:
V-Lock must only be used in weather protected areas.
V-Lock can be installed vertically or horizontally.
For vertical mounting, ensure V-Lock is oriented right side up as indicated by the unit label.
For horizontal mounting, ensure V-Lock is only installed above the door.
For ideal operation, a door gap of 3mm to 8mm is required between lock unit and strike plate.
Ensure strike plate is fl ush-mounted or recessed, well-supported and securely fastened to increase overall holding force and
security of installation.
INSTALLATION INSTRUCTIONS
ES8000 V-LOCK
P
age
1
DRAWINGS NOT TO SCALE. INFORMATION IN THIS DATASHEET MAY BE CHANGED WITHOUT NOTICE.
P
age
4
SPECIFICATIONS
An ASSA ABLOY Group brand
DA0076, Issue 8: 13 May 2008
LOCK MODE CONFIGURATION
STEP 3
- Change jumper position on Printed
Circuit Board beneath the red
re-sealable sticker as shown below:
Power-to-Open
(Fail Secure)
Power-to-Lock
(Fail Safe)
STEP 2
- Rotate Latch Plate screw beneath
the red re-sealable sticker according to
orientation shown below:
Turn counter-clockwise
180
o
for Power-to-Open
(Fail Secure)
Turn clockwise 180
o
for
Power-to-Lock (Fail Safe)
STEP 1
- Loosen both screws on side of lock
body.
- Slide screws in direction required until
stop at end of slot is reached.
- Hold in position and re-tighten screws.
PTL
PTO
If the lock had been installed or previously operated, the latch plate screw (STEP 3) may not be visible. To
change lock mode confi guration, contact your distributor for additional instructions.
Ensure all re-sealable stickers and screws are re-attached after confi guration to prevent ingress of dust.
5 Year Limited Warranty
ASSA ABLOY Australia guarantees for a period of 5 years in accordance with Trimec’s Standard Warranty Conditions, against defects in
manufacture, workmanship or materials, provided that all electrical and mechanical installation requirements are adhered to as per this
datasheet. All third party and consequential claims are expressly excluded from this warranty.
warranty
ASSA ABLOY Australia
2/16 Atkinson Road
Taren Point 2229
NSW, Australia
www.assaabloyasiapacifi c.com
Parameter Specifi cation
Door Gap Between 3mm to 8mm only
Lock Monitor Output Voltage free changeover switch contacts rated for 48vDC / 100mA
Holding Force AS4145.2 - 1993: Passed S3 (611kg for 1 minute)
Capable of 1000kg if strike plate is fully supported
Release under Side Load 15kg max at bolt with motorised unlocking (3 wire control)
3kg max at bolt with Power-To-Lock (Fail Safe) unlocking and 2 wire control
Bolt Dimensions Diameter = 11mm
Projection = 20.5mm
Power Supply (12-28VDC) Regulation better than +/- 2%
1Amp Power supply required
Current Draw Power to Lock holding current 130mA
Power to Open holding current 30mA
Initial locking and unlocking current draw higher
Misalignment tolerance +/- 3.5mm
Operating Temperature -10
o
C to +50
o
C at 90% RH
Durability > 300,000 cycles
Certifi cations 2-hour fi re rating
WITH 30MM FACEPLATE