Waveform | Sine |
---|---|
Efficiency | 97 % |
Output power | 425 W |
UPS topology | Standby (Offline) |
Input frequency | 60 Hz |
Maximum current | 12 A |
Audible alarm(s) | Yes |
Surge energy rating | 510 J |
Output power capacity | 0.7 kVA |
Number of input phases | 2 |
Output voltage regulation | 5 % |
Input operation voltage (max) | 120 V |
Input operation voltage (min) | - V |
Output operation voltage (min) | 110 V |
Battery recharge time | 4.5 h |
Typical backup time at full load | 3 min |
Typical backup time at half load | 11 min |
Form factor | Tower |
Cable length | 1.8 m |
Product color | White |
LED indicators | Power |
Housing material | Polyvinyl chloride (PVC) |
Power plug | NEMA 5-15P |
AC outlet types | NEMA 5–15R |
AC outlets quantity | 6 AC outlet(s) |
USB 2.0 ports quantity | 1 |
Storage temperature (T-T) | -15 - 50 °C |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95 % |
Quantity per pallet | 1 pc(s) |
Cables included | USB cable |
Depth | 190 mm |
---|---|
Width | 133 mm |
Height | 273 mm |
Weight | 6900 g |
Package depth | 267 mm |
Package width | 216 mm |
Package height | 356 mm |
Package weight | 7800 g |
Install UPS indoors, away from moisture, heat, dust, and direct sunlight.
Connect UPS to grounded outlet, do not modify plug or use adapters.
Do not use for life-support, avoid connecting surge suppressors to UPS output.
No user-serviceable parts, avoid shock/burns, do not dispose in fire, use insulated tools.
Connect UPS to a grounded AC outlet, avoiding heavy load circuits.
Connect computer equipment to UPS/Surge outlets, avoid high power draw devices.
Press ON/OFF button to toggle between ON and OFF modes.
Protects against surges over phone/data lines; connect wall to IN, equipment to OUT.
Connect UPS to computer via USB for monitoring software and auto-shutdown.
Details ON/OFF button for switching modes and cold-starting the UPS.
Silences on-battery alarms and runs UPS self-tests to check performance.
Explains LINE POWER, BATTERY POWER, and REPLACE BATTERY indicator lights.
Describes "UPS/Surge" and "Surge-Only" receptacles for power and surge protection.
Protects against surges over telephone or data lines; optional connection.
Connects UPS to computer for software monitoring and unattended shutdown.
Notes that battery replacement requires qualified personnel and refers to safety section.
Adjusts UPS sensitivity to input power waveform distortions to reduce battery switching.
Instructions for storing the UPS, including battery recharge recommendations.
Guidance on returning the UPS for service, packing, and providing problem description.