Output Input
OutputVoltAmpCapacity(VA)
OutputkVACapacity(kVA)
OutputWattCapacity(watt)
Outputpowerfactor
Nominal output voltage(s)
supported
Frequency compatibility
Outputvoltageregulation
(line mode)
Outputvoltageregulation
(battery mode)
Built-inUPSoutputreceptacles
Built-incontrollableswitched
load banks
OutputACwaveform(ACmode)
OutputACwaveform(battery
mode)
1500
1.5
980
0.7
120V
60Hz
-18%,+8%
±5%
65-15Routlet(s)
Oneswitchablesingle-outlet
5-15Rloadbank
Sine Wave
PWM Sine Wave
Ratedinputcurrent
(at maximum load)
Nominal input voltage(s)
supported
UPS input connection type
Inputcircuitbreaker
UPS input cord length ()
UPS input cord length (m)
Recommendedelectrical
service
12A
120VAC
5-15P
15A
6
1.8
15A,120V
Battery Voltage Regulation
Full load runtime (minutes)
Half load runtime (minutes)
DCsystemvoltage(VDC)
Batteryrechargerate
(included batteries)
Replacementbattery
cartridge (internal UPS
battery replacement)
Batteryaccess
Batteryreplacement
description
7minute(980W)
20minute(490W)
36VDC
Lessthan4hoursfrom
10%to90%
RBC53
Batteryaccessdoor
Hot-swappable, user
replaceable batteries
Voltageregulation
description
Overvoltagecorrection
Undervoltage correction
Severe undervoltage
correction
AutomaticVoltage
Regulation(AVR)maintains
line power operation with
an input voltage range of
75to147
Inputvoltagesbetween
128and147arereduced
by12%
Inputvoltagesbetween93
and107areboosted
by14%
Inputvoltagesbetween75
and92areboostedby30%
LEDs Alarms and Switches Surge/Noise Suppression
LED indicators
Alarms
Alarm cancel operation
Switches
5 LEDs indicate line power,
battery power, overload,
voltage regulation and battery
low/replace status
Audible alarm indicates
power-failure, overload and
low-battery conditions
Power-fail alarm can be silenced
using alarm-cancel switch; once
silenced, alarm will re-sound to
indicate low-battery status
2Switchescontrolo/onpower
status and alarm-cancel/
self-test operation
UPS AC suppression joule
rating
UPS AC suppression
response time
EMI/RFIACnoise
suppression
480J
Instantaneous
Yes
SPECIFICATIONS
• Includes1USBand1DB9monitoringportforremote
monitoring of UPS status and site power conditions
• Communicationsportsenablesafeunattendedshutdown
without data loss during extended power failures
• CommunicationsportssupportmessagingofUPSand
line power status, including on-battery, low-battery,
power-restored, AC line voltage, DC battery voltage and
battery capacity
• Communicationsportssupporttimedinvertershuto
aerunattendedshutdown,activateself-testand10
second reboot of connected equipment
• PowerAlertUPSmonitoringandunattendedshutdown
soware with complete cabling included
• SupportsTrippLite’sWatchDogsowareapplicationto
restore unresponsive programs by automatically restarting
them and rebooting completely locked computers by
automaticallyswitchingUPSpoweroandbackonagain
• Noticationofsystemstatusvia5LEDsandmultifunction
audible alarms
• WallmountablewithUPSWMwallmountbracket
• Attractivesmallfootprintbeigetowerhousingusesless
than 66 square inches
• Hot-swappable/userreplaceablebatteriesallowon-site
battery replacement
• ColdstartcapabilityenablesUPSturn-oninbatterymode
during blackout conditions
• UL(U.S.),cUL(Canada),NOM(Mexico),ClassA(Emissions)
•
$
250,000UltimateLifetimeInsurance(U.S.andCanadaonly)
• 2-yearmanufacturersproductwarrantywith
$
250,000
connected equipment insurance (U.S. and Canada only)