Output Input
OutputVoltAmpCapacity(VA)
OutputkVACapacity(kVA)
OutputWattCapacity(watt)
Outputpowerfactor
Nominal output voltage(s)
supported
Frequency compatibility
Outputvoltageregulation
(line mode)
Outputvoltageregulation
(battery mode)
Built-inUPSoutputreceptacles
Built-incontrollableswitched
load banks
OutputACwaveform(ACmode)
OutputACwaveform(battery
mode)
1500
1.5
980
0.7
120V
60Hz
-18%,+8%
±5%
65-15Routlet(s)
Oneswitchablesingle-outlet
5-15Rloadbank
Sine Wave
PWM Sine Wave
Ratedinputcurrent
(at maximum load)
Nominal input voltage(s)
supported
UPS input connection type
Inputcircuitbreaker
UPS input cord length ()
UPS input cord length (m)
Recommendedelectrical
service
12A
120VAC
5-15P
15A
6
1.8
15A,120V
Battery Voltage Regulation
Full load runtime (minutes)
Half load runtime (minutes)
DCsystemvoltage(VDC)
Batteryrechargerate
(included batteries)
Replacementbattery
cartridge (internal UPS
battery replacement)
Batteryaccess
Batteryreplacement
description
7minute(980W)
20minute(490W)
36VDC
Lessthan4hoursfrom
10%to90%
RBC53
Batteryaccessdoor
Hot-swappable, user
replaceable batteries
Voltageregulation
description
Overvoltagecorrection
Undervoltage correction
Severe undervoltage
correction
AutomaticVoltage
Regulation(AVR)maintains
line power operation with
an input voltage range of
75to147
Inputvoltagesbetween
128and147arereduced
by12%
Inputvoltagesbetween93
and107areboosted
by14%
Inputvoltagesbetween75
and92areboostedby30%
LEDs Alarms and Switches Surge/Noise Suppression
LED indicators
Alarms
Alarm cancel operation
Switches
5 LEDs indicate line power,
battery power, overload,
voltage regulation and battery
low/replace status
Audible alarm indicates
power-failure, overload and
low-battery conditions
Power-fail alarm can be silenced
using alarm-cancel switch; once
silenced, alarm will re-sound to
indicate low-battery status
2Switchescontrolo/onpower
status and alarm-cancel/
self-test operation
UPS AC suppression joule
rating
UPS AC suppression
response time
EMI/RFIACnoise
suppression
480J
Instantaneous
Yes
SPECIFICATIONS
• Includes1USBand1DB9monitoringportforremote
monitoring of UPS status and site power conditions
• Communicationsportsenablesafeunattendedshutdown
without data loss during extended power failures
• CommunicationsportssupportmessagingofUPSand
line power status, including on-battery, low-battery,
power-restored, AC line voltage, DC battery voltage and
battery capacity
• Communicationsportssupporttimedinvertershuto
aerunattendedshutdown,activateself-testand10
second reboot of connected equipment
• PowerAlertUPSmonitoringandunattendedshutdown
soware with complete cabling included
• SupportsTrippLite’sWatchDogsowareapplicationto
restore unresponsive programs by automatically restarting
them and rebooting completely locked computers by
automaticallyswitchingUPSpoweroandbackonagain
• Noticationofsystemstatusvia5LEDsandmultifunction
audible alarms
• WallmountablewithUPSWMwallmountbracket
• Attractivesmallfootprintbeigetowerhousingusesless
than 66 square inches
• Hot-swappable/userreplaceablebatteriesallowon-site
battery replacement
• ColdstartcapabilityenablesUPSturn-oninbatterymode
during blackout conditions
• UL(U.S.),cUL(Canada),NOM(Mexico),ClassA(Emissions)
•
$
250,000UltimateLifetimeInsurance(U.S.andCanadaonly)
• 2-yearmanufacturersproductwarrantywith
$
250,000
connected equipment insurance (U.S. and Canada only)

Other manuals for Tripp Lite SmartPro