EasyManua.ls Logo

TriTherma MQD-8 - User Manual

TriTherma MQD-8
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
(Heating, Cooling and Domestic Hot Water)
MANUAL OF INSTALLATION,
OPERATION AND MAINTENANCE
SPLIT MULTIFUNCTIONAL
AIR TO WATER HEAT PUMP
MQD-14
MQD-17
MQD-20
MQD-8
MQD-23
MQD-11

Questions and Answers

  • S
    Sean KhanAug 19, 2025
    What to do if the TriTherma MQD-8 Heat Pump compressor overheats?
    • T
      thompsonlarryAug 19, 2025
      If the TriTherma Heat Pump compressor overheats, refer to the function book for the meaning of fault code E1. Alternatively, wait for the outdoor unit LED light to flash one time with an interval of 5 seconds.
  • M
    Michelle LawsonAug 21, 2025
    What should I do if my TriTherma Heat Pump shows a Coil over heating protection error?
    • A
      Anthony DeckerAug 22, 2025
      If your TriTherma Heat Pump shows a coil over heating protection error, check the function book for the meaning of fault code E8. Another option is to wait for the outdoor unit LED light to flash 4 times with an interval of 5 seconds.
  • L
    Laura BarrettAug 25, 2025
    What should I do if my TriTherma MQD-8 Heat Pump displays an Over current protection error?
    • C
      Cathy HernandezAug 25, 2025
      If your TriTherma Heat Pump displays an over current protection error, check the function book for the meaning of fault code P4. The specific solution might depend on the outdoor unit.
  • B
    beckblakeAug 26, 2025
    What should I do if my TriTherma MQD-8 displays a Low pressure protection error?
    • A
      Alexander BakerAug 26, 2025
      If your TriTherma Heat Pump displays a low pressure protection error, check the function book for the meaning of fault code P2. You can also wait for the outdoor unit LED light to flash 7 times with an interval of 5 seconds.
  • L
    Leslie JohnstonAug 28, 2025
    What should I do if my TriTherma Heat Pump displays an Outdoor wrong phase error?
    • T
      Todd BennettAug 28, 2025
      If your TriTherma Heat Pump displays an outdoor wrong phase error, check the function book for the meaning of fault code P8. You can also wait for the outdoor unit LED light to flash 9 times with an interval of 5 seconds.
  • T
    thompsonryanAug 30, 2025
    What to do if the TriTherma MQD-8 has an ambient temp. sensor Error?
    • J
      john57Aug 30, 2025
      If the TriTherma Heat Pump has an ambient temp. sensor Error, check the function book for the meaning of fault code E2. Alternatively, wait for the outdoor unit LED light to flash 2 times with an interval of 5 seconds.
  • S
    sandra46Sep 1, 2025
    What to do if the TriTherma MQD-8 has a Pipe temp. sensor Error?
    • E
      Edward BushSep 1, 2025
      If the TriTherma Heat Pump has a Pipe temp. sensor Error, check the function book for the meaning of fault code E3. Alternatively, wait for the outdoor unit LED light to flash 3 times with an interval of 5 seconds.
  • C
    Christina AdkinsSep 3, 2025
    What happens when the TriTherma MQD-8 Heat Pump's Return water temp. sensor fails?
    • K
      Kevin SchultzSep 3, 2025
      When the TriTherma Heat Pump's Return water temp. sensor fails, the compressor will stop.
  • A
    Andrew MurraySep 5, 2025
    What happens when there is an AC Antifreeze protect issue with my TriTherma MQD-8 Heat Pump?
    • M
      Michelle NelsonSep 5, 2025
      If there is an AC Antifreeze protect issue with your TriTherma Heat Pump, the compressor will stop.
  • B
    Brian RichardsonSep 7, 2025
    What happens when the TriTherma MQD-8's AC out water temp. sensor malfunctions?
    • D
      diamondzimmermanSep 7, 2025
      When the TriTherma Heat Pump's AC out water temp. sensor malfunctions, the compressor will stop.

TriTherma MQD-8 Specifications

General IconGeneral
BrandTriTherma
ModelMQD-8
CategoryHeat Pump
LanguageEnglish