Questions and Answers

  • W
    William JonesAug 10, 2025
    Why does my Triton Water Filtration System have high TDS in the product water?
    • N
      Nancy BakerAug 10, 2025
      If the product water from your Triton Water Filtration System has a high content of dissolved salts (TDS), it could be due to several reasons. Check if the waste valve is open and adjust it accordingly. Inspect the osmosis membrane seal inside the membrane housing to ensure it's properly seated and in good condition, without any leaks in the o-ring or cap. If the reverse osmosis membrane is exhausted (average life is about 2 years), replace it. Also, verify that the product and wastewater lines are not reversed, correcting them if necessary. Finally, consider whether the amount of TDS in the feedwater has changed, as an increase in raw water TDS can affect product water quality. You should also refer to other causes related to insufficient pressure.
  • B
    Breanna MillerAug 28, 2025
    Why is my Triton Water Filtration System producing no or too little water?
    • A
      andersonjamesAug 28, 2025
      If your Triton Water Filtration System is producing no product or too little water, the membrane might be saturated or dirty, requiring cleaning or replacement. Also, check your feed water temperature and correction factor, ensuring the flow is at an acceptable level. Refer to other sections in this manual that address issues of not having enough pressure.
  • S
    Stacey GarciaNov 3, 2025
    How to troubleshoot a Triton Water Filtration System that will not start?
    • J
      Jennifer HurleyNov 3, 2025
      If your Triton Water Filtration System isn't starting, begin by ensuring the power switch is in the AUTO position and that the system is properly plugged into a functioning power outlet. Check the 2AMP fuse on the back of the controller. Verify that the feed valve is fully open to provide sufficient inlet pressure. Also, confirm that your pre-treatment pump is operating correctly to supply pressure to the Reverse Osmosis system. Check the low-pressure switch and replace if needed. Ensure pretreatment pressure drop doesn't cause insufficient water pressure. Inspect the magnetic starter and level switch, replacing the coil if necessary and checking if the storage tank is filled. If the pump motor seems to be the issue, use a multimeter to check all electrical connections and switches to pinp...
  • V
    Veronica WhiteNov 15, 2025
    What to do if there's no high pressure in my Triton Water Filtration System?
    • R
      Russell WilliamsNov 15, 2025
      If there's no high pressure in your Triton Water Filtration System, first allow the system to run for at least 5 minutes to purge any air, as some air is normal. Then, check if the waste valve is open and adjust the pressure to the recommended level for your membrane type. Ensure the recirculation valve isn't completely open and adjust it as needed. Verify the pressure gauge is working correctly; replace it if faulty. Inspect all tubing and hoses for kinks or blockages, replacing any damaged sections. Check the pump impellers for wear or damage and replace if necessary. Also, make sure the power supply matches the voltage requirements of your system. Finally, check the solenoid valve for clogs or faults, and ensure sufficient water pressure is feeding the system to prevent the pump from su...
  • M
    markjenningsNov 20, 2025
    Why does my Triton Water Filtration System water taste and smell different?
    • T
      Tammy MarshallNov 20, 2025
      If your Triton Water Filtration System's product water has a different taste and odor, it could be due to a saturated and polluted membrane (bacteria), which may require chemical cleaning or replacement. Check for any foreign matter in the storage tank, and if present, clean and sanitize the tank. Consider replacing the filter cartridges and ensure that the product and wastewater lines are not reversed. If they are, correct the connections. If you have a post-carbon filter, replace it if it's exhausted. Also, the membrane life is on average 2 years, so replace the membrane if its life has been exhausted. Check that the membrane is installed properly and for leaks in the o-ring or cap causing a mixture of water and waste-product. Finally, consider integrating special pre-treatment to remove...

Summary

Introduction

System Specifications

Details model, production, membrane, pressure, dimensions, weight, and power supply.

Principles of Reverse Osmosis

Reverse Osmosis Process Explained

Explains the RO process, semipermeable membranes, and particle rejection.

Factors Affecting Membrane Life

Lists 5 key factors impacting membrane performance and longevity.

RO Terms and Definitions

Defines terms like feed water, product water, concentrate, GPD, PPM, recovery, and rejection.

System Components

Prefilter Pressure Gauge

Describes the 0-100 psi gauge for pre-filter pressure monitoring.

System Pressure Gauge

Describes the 0-300 psi gauge for system pressure and adjustment.

Flowmeters for Water Measurement

Explains meters for measuring waste water and purified product water.

RO Module and Waste Valve Function

Defines the RO module and the waste valve controlling water flow and pressure.

Recirculation Valve

Valve for adjusting recirculating waste water to refine pressure.

Pre-Filter Stages

Details the 5-micron sediment and carbon block filters for particle removal.

High Pressure Pump

Pump creating pressure for RO, adjustable via waste/recirculation valves.

Control Box and Inlet Solenoid Valve

Electronic controller, security features, and NC solenoid valve for water supply control.

Pre Installation References

Water Inlet and Outlet Connections

Describes inlet feed water, outlet product water, and outlet waste water connections.

Electrical & Level Switch Wiring

Details 120V power, local compliance, and storage tank level switch wiring.

Reverse Osmosis System Installation

Installation Steps

Steps for choosing location, installing filters, membranes, valves, and electrical connections.

Membrane Installation

Membrane Insertion Guidance

Guidance on inserting membranes into housing, noting arrow direction and seals.

Programming the EC-100 Controller

Navigation and Programming Menu

Explains the controller interface, keys (SET, UP, DOWN), and main screen display.

Controller Programming Overview

Details how to adjust pre-set parameters (P1-P6) for system operation.

Controller Screen Display Meanings

Explains the meaning of TIMER, TDS, LOW, FLUSH, MAIN PUMP, FULL indicators.

Controller Parameter Settings

Details adjustable parameters (P1-P6) for flush, delays, TDS range, and sensitivity.

Cable Connection and TDS Calibration

System Cable Identification

Identifies wire colors for various system functions and switches.

TDS Sensor Calibration Steps

Guides on calibrating the TDS sensor using calibration solutions and parameter P6.

Start-Up Procedures

System Startup Procedure

Detailed step-by-step guide for initial system startup and checks.

Post-Startup System Tests

Procedures for monitoring TDS, checking rejection rates, and verifying level switch function.

Troubleshooting Guides

System Will Not Start

Lists possible causes and solutions for the system failing to start.

Troubleshooting: Low System Pressure

Identifies issues causing low system pressure and their remedies.

Troubleshooting: Low Flow or Rejection

Addresses problems with low water flow or poor rejection rates.

Troubleshooting: Insufficient Water Production

Covers causes for insufficient water output and low production.

Troubleshooting: High Product TDS

Solutions for high TDS levels in the product water.

Troubleshooting: Water Taste and Odor

Explains how to resolve taste and odor issues in the output water.

Pre-Treatment Requirements

Pre-Treatment: Water Disinfection

Advises on disinfection for microbiologically unsafe water before purification.

Pre-Treatment: Filters and Softeners

Explains sediment filters, carbon filters, and water softeners for membrane protection.

Electrical Installation Options

Electrical Setup: Atmospheric Tank

Diagram and explanation for connecting to an atmospheric storage tank.

Electrical Setup: Pressurized Tank

Diagram and explanation for connecting to a pressurized storage tank.

Liability and Warranty

Legal: Terms of Sale and Payment

Covers general terms of sale, prices, and payment conditions.

Legal: Warranty and Remedies

Details the limited warranty, remedies, and exclusions for the product.

Legal: Indemnity, Taxes, and Rights

Covers buyer's responsibilities for IP infringement, taxes, and seller's rights.

Triton IXC-850 Series Specifications

General IconGeneral
BrandTriton
ModelIXC-850 Series
CategoryWater Filtration Systems
LanguageEnglish