17
Possible Selectrix Settings
● Programming Possibilities:
– Locomotive Addresses 01 ... 111 (03)
– Maximum Speed 1 ... 7 (5)
– Acceleration/ Braking Delay (AFB) 1 ... 7 (4)
– Pulse Width (Duration) 1 ... 4 (2)
– Signal Braking Block 1 / 2 part (1)
● Additional Settings:
– Swapping Connections 0 ... 7 (4)
– AFB Effectiveness 1 ... 2 (1)
– Variations in Motor Control 1 ... 4 (3)
( ) = Setting done at the factory
Information about Selectrix Operation:
If a locomotive enters a braking block that is on
against the direction of travel for that block, the
headlight(s) for that locomotive may go out depending
on how that locomotive is wired. The headlight(s)
will come back on after leaving the braking block.
Selectrix Operation
Place the locomotive on the programming track
and read out the settings for the decoder. The basic
setting should be 03-542. Temporarily run the loco-
motive with these settings and check out the func-
tions available on the locomotive. After you have
completed this first testing period, you can adapt
the parameters for the locomotive to your needs.
If the reader unit shows “Lesefehler” (“Reader Error”),
check again to make sure that the locomotive is
properly wired and reread the instructions for making
connections to the programming track. In this situa-
tion do not under any circumstances start running
the locomotive on your layout!