EasyManuals Logo

Trotec B 6 E User Manual

Trotec B 6 E
19 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
EN 11
humidifier B 6 E
Night mode
The device humidifies the air constantly and regardless of the
relative room humidity.
In night mode, the timer is automatically set to 8h.
The desired relative room humidity cannot be adjusted in this
operating mode.
The nebulizer intensity can be adjusted at any time in this
operating mode.
The display switches off after approx. 1min and only switches
back on when a button is pressed.
In night mode, the device operates with the following settings:
If the current relative room humidity is equal to or higher
than 60%, the device humidifies the air at nebulizer
intensity level 1.
If the current relative room humidity is between 40% and
60%, the device humidifies the air with the nebulizer
intensity set.
Setting the timer
For the device to switch off automatically after a predefined
number of hours (up to max. 12h) you can programme the
timer.
The timer can be programmed in increments of 1hour
(1 to 12h) in manual humidification mode and automatic mode.
Please proceed as follows to programme automatic switch-off:
1. Press the Timer button(25).
ð The number of hours flashes on the segment
display(15).
2. Press the Timer button(25) until the desired number of
hours is displayed.
3. Wait a moment until the number of hours stops flashing.
ð The timer setting equals the desired number of hours.
ð The current room humidity is displayed again.
ð The device switches off after the set period of time.
Note regarding automatic switch-off:
Pressing the On/Off button(26) deactivates the automatic
switch-off function.
The timer stops when the lacking water indication(17)
lights up. The timer continues to run as soon as the water
tank is full again.
Switching ionization on or off
Ionization can be switched on as needed. The device will then
release ions for additional air purification. The released ions
remove pollen, dust, viruses and bacteria from the room air.
Ionization can be switched on in any operating mode.
1. Press the Timer button(25) for approx. 5 s to switch
ionization on or off.
ð When ionization is activated, the anion indication(20)
will be shown on the display.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch off the device.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Empty the water tank.
Empty the lower part.
Use a cloth to wipe all parts of the device dry.
Clean the device according to the Maintenance chapter.
Store the device according to the Storage chapter.
Available accessories
Warning
Only use accessories and additional equipment
specified in the operating manual.
Using insertion tools or accessories other than those
specified in the operating manual may cause a risk of
injury.
Designation Article number
SecoSan
®
Stick10 6.100.004.110

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trotec B 6 E and is the answer not in the manual?

Trotec B 6 E Specifications

General IconGeneral
BrandTrotec
ModelB 6 E
CategoryHumidifier
LanguageEnglish

Related product manuals