Summary

Section 1 General Description

1.1 Introduction

Overview of the TC240 DC/DC Power Converter, its purpose, and key features.

1.2 Technical Specifications

Details the electrical and physical attributes of the TC240 DC/DC Power Converter.

Section 2 Pre-Installation Considerations

2.1 Cooling

Explains the cooling methods for the TC240, primarily passive conduction and radiation.

2.2 Equipment Location

Discusses flexibility in mounting location, altitude, temperature, and humidity resistance.

2.3 Routing of Cables

Provides guidance on routing heavy gauge wires and avoiding hazards like chafing.

2.4 Limitations

Outlines TSO approval standards, installation approval, and operational temperature limits.

2.5 Modification

Explains nameplate information and modification (MOD) status identification.

Section 3 Installation

3.1 General Information

Provides interconnect diagrams, mounting dimensions, and installation information.

3.2 Unpacking and Inspecting Equipment

Details the process of unpacking and inspecting the TC240 DC/DC Converter.

3.3 Cable Harness

Instructions for constructing the cable harness, including wire gauge selection.

3.4 Mounting

Details the base mounting procedure and screw requirements for the TC240.

3.5 Installation Caution

A critical warning against connecting the output to another power source.

3.6 Installation Completion

Steps for verifying output and functionality after installation.

Section 4 Operation

4.1 Electrical Performance

Explains the TC240's performance as a DC/DC converter and output current vs. voltage.

4.2 Protective Features

Details features like remote on/off, input voltage limit, over-temperature, and short circuit protection.

Section 5 Conformance

5.1 Instructions for Continued Airworthiness

States that no periodic maintenance or calibration is required for continued airworthiness.

5.2 Environmental Qualification Statement

Lists environmental test conditions and categories met by the TC240.

True blue power TC240 Specifications

General IconGeneral
Power240 W
Output Current10 A
CoolingConvection
Output Voltage24V DC
Efficiency90%
ProtectionOver Voltage, Short Circuit