8
Maintenance
The power supply must always be completely discon-
nected before performing any maintenance work on the
device.
Clean the device and the ventilation slits with a dry and fluff-
free cloth.
Disposal
The device must be disposed of in line with the administra-
tive regulations of the respective country in which it is used.
National regulations and laws (in Germany, for example, the
End-of-life Vehicle Regulation) must be observed.
Technical data
Power supply
AC voltage 230 V / 50 Hz, single-phase
Range approx. 205 V – 265 V / 45 – 65 Hz
Output
Sustained short-circuit protection
Idle-proof
Output voltage
12 V DC + 6 % (< 0.05 % / °C)
Output power
450 W at 20 °C, above this, automatic power reduction
Residual ripple
< 0,18 Vpp
Storage temperature
-20 – +80 °C
Air humidity
5 – 95 % without thawing
Noise
< 10 dBA (at a distance of 1.5 m)
Dimensions (L x W x H)
360 x 220 x 103 mm
Weight
2.5 kg
The right to effect technical modifications is reserved!
Troubleshooting
Error Rectification
Connected consumers do
not work.
Check all connections are
correct.
Pull out the female device
plug to disconnect the
device from the 230 V AC
voltage mains. Wait 15 s –
connect the female device
plug to the device again.
Check all fuses and the
mains supply connection.
The maximum output
current is not achieved.
The device is too warm,
ensure better ventilation
of the device.
If these measures do not solve the problem, please
contact the Truma Service Centre.