Gebrauchsanweisung Seite 3
Einbauanweisung Seite 6
Operating instructions
Page 7
Installation instructions Page 10
Mode d‘emploi Page 11
Instructions de montage Page 14
Istruzioni per l‘uso Pagina 15
Istruzioni di montaggio Pagina 18
Gebruiksaanwijzing Pagina 19
Inbouwhandleiding Pagina 22
Brugsanvisning Side 23
Monteringsanvisning Side 26
Instrucciones de uso Página 27
Instrucciones de montaje Página 30
Bruksanvisning Sida 31
Monteringsanvisning Sida 34
APS 450-HF
Question and Answer IconNeed help?

Do you have a question about the Truma APS 450-HF and is the answer not in the manual?

Truma APS 450-HF Specifications

General IconGeneral
Output Voltage13.8 V DC
Output Power450 W
Battery TypeLead-acid, AGM, Gel
Charging Voltage13.8 V DC
Protection FeaturesOverload, short circuit

Summary

Operating Instructions

Application Purpose

Device generates stabilised 12V DC from 230V AC for consumers in caravans.

Improper Use

Device is not a charger and may not be used to charge batteries.

Description of Device

Supplies filtered and stabilised 12V DC for all outputs, secured with plug-in fuses.

Connections and Fuses

Overview of connection terminals (X0, X1, X2) and fuses (F1-F5) with their functions.

Commissioning

Device is operational upon connection to the mains supply.

Fuse Change Procedure

Procedure for replacing faulty fuses with the same type after rectifying the fault.

Removing Clamping Space Cover

Instructions on how to remove and attach the clamping space cover for fuse access.

Maintenance and Disposal

Maintenance Safety

Disconnect power supply before maintenance; clean with dry cloth.

Disposal Guidelines

Dispose according to administrative regulations and national laws.

Technical Data and Troubleshooting

Technical Specifications

Details on power supply, output voltage, power, dimensions, and weight.

Troubleshooting Guide

Lists common errors, their causes, and rectification steps.

Installation Instructions

Installation Safety

Qualified technicians must disconnect power and use correct cable/fuses for installation.

Assembly Requirements

Device installation: away from damp, clean, dry, well-ventilated, free slits.

Connection Safety

Ensure power is interrupted before connecting/disconnecting cables.

Main Supply Connection

Connect to mains power supply according to local regulations by an expert.