9
Fuse change (TEB-3 – 12 V only)
Observe the ESD regulations.
The appliance fuse (F1) is on the electronic control unit in the
appliance.
Switch fan so that it is voltage-free (disconnect battery, dis-
connect mains plug if necessary).
Remove connectors from power supply and control panel.
Remove 2 screws (1) from the housing – take off housing.
Hold the edges of the PCB and pull it out of the housing.
Always replace defective fuses with identical fuses (see
“Technical data”).
Insert PCB into the housing.
Secure housing to fan with 2 screws (1) after changing the
fuse.
Attach connectors of control panel and power supply (ob-
serve correct polarity, otherwise the control panel will not
function and the fan will run in the wrong direction).
Reconnect battery, re-establish mains connection if necessary.
F1
1
TN-3 – 230 V
External control panel
1
2
3
4
5
230 V ~
Trumavent
d
c
a
b
a = Control knob for fan power (1 – 5)
b = Rotary switch for operating modes
c = Off
d = On, manual fan power setting
Set required speed with control knob (a).
Disposal
The appliance must be disposed of in accordance with the ad-
ministrative regulations of the respective country in which it is
used. National regulations and laws (in Germany, for example,
the End-of-life Vehicle Regulation) must be observed.