Respirator Fit Testing
8030 and
8038
Respirator Fit Testers
Operation and Service Manual
P/N 6001868, Revision B
August 2008

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the TSI Incorporated portacount pro 8030 and is the answer not in the manual?

TSI Incorporated portacount pro 8030 Specifications

General IconGeneral
ModelPortaCount Pro 8030
TypeRespirator Fit Tester
Concentration Range0 to 100, 000 particles/cm³
Light SourceLaser Diode
Battery LifeUp to 8 hours
Humidity Range0 to 95% RH, non-condensing
PowerAC adapter or rechargeable batteries
Operating Temperature10 to 35 °C (50 to 95 °F)
Storage Temperature-20 to 60 °C (-4 to 140 °F)
Data StorageInternal memory for test results
DisplayColor touchscreen
Communication InterfaceUSB
ComplianceCE

Summary

About Respirators and Fit Testing

Probes for Disposable Respirators

Details how to fit test disposable respirators using probes and the TSI Model 8025-N95 Probe Kit.

Inserting a Test Probe in a Disposable Respirator

Provides step-by-step instructions and warnings for installing a probe into a disposable respirator.

Conducting a Fit Test with the PORTACOUNT PRO Respirator Fit Tester

Step 1: Prepare the PORTACOUNT PRO for Fit Testing

Details the initial setup, including filling the alcohol cartridge and warnings.

Step 2: Attach Flash Drive and Select Database

Guides on connecting a flash drive for database selection and saving data.

Step 3: Run Daily Checks

Explains the importance and procedure for performing daily maintenance checks on the instrument.

Step 4: Conducting Fit Tests

Provides instructions on performing the actual fit test, including subject preparation and exercises.

Step 5: Record Results

Details how to record fit test results, whether manually or via database.

Operating Modes and User Interface

Modes of Operation

Differentiates between External Control (FITPRO software) and Stand-alone modes.

Service and Maintenance

Recalibration Interval Recommendations

Recommends annual recalibration and provides contact information for service.

Troubleshooting

Symptom, Cause, and Solution Guide

Lists common symptoms, their possible causes, and recommended solutions.

Appendix A Specifications

Appendix B Theory of Operation

How the PORTACOUNT PRO Works

Explains the principle of measuring respirator fit by comparing particle concentrations.

Appendix C Calculating Fit Factor

Fit Factor Calculation Formula

Details the formula and method used to calculate the fit factor.

Appendix D Calculating Particle Concentration

Appendix E Timing in Fit Test Mode

Appendix F Using the PORTACOUNT PRO to Fit Test Positive Pressure Respirators