2. Installation Instruction
2.1 Choose the installation point
Straight pipe installation requirement(D is pipe diameter), upstream 3D, downstream 0D,
make sure the pipe full of liquid completely.
Correct installation point Wrong installation point
At the lowest point in the pipe system;
Vertical upward or slanted upward pipe;
Upstream straight pipe3D
At the highest point in the pipe system;
Vertical downward or slanted downward
pipe; Upstream straight pipe3D
psArrow direction is fluid flow direction.
2.2 Installation Method
1.Confirm installation dimension
2.Cup off
Water meter length L+2pcs sealing gasket thickness
+
10mm
3.Install matching flanges
4.Flanges position
5.Flanges welding
6.After cooling, install with sealing gasket,
fasten screws
Three screws on an average positioning flanges,
spot-welding fixing
Take off the water meter,
finish full welding of the flange