Safety instructions for installation, troubleshooting, and repairs of the monitoring system.
Information for contacting the TSUN Service line for technical problems.
Lists the components included in the Talent-MG2 monitoring system package.
Instructions for connecting antennas to the Wi-Fi/GPRS and 2.4G ports.
Procedure for inserting a SIM card into the SIM Card Slot (for Talent-MG2-GP).
Instructions for screwing the bracket onto the wall for device mounting.
Guide on attaching the monitor device to the bracket securely.
Instructions for powering on the monitor device.
Connecting to the MG2-W wireless network via computer or mobile phone.
Accessing the Wi-Fi configuration page by entering the IP address in a browser.
Navigating to the Wi-Fi parameter menu for configuration.
Searching for and selecting the Wi-Fi name to connect to the monitoring device.
Entering the Wi-Fi password and saving the configuration settings.
Restarting the device for configurations to take effect.
Installing the microinverter system and connecting the monitoring device.
Creating a new user account on the monitoring platform.
Logging into the platform and configuring the network for the monitoring system.
Adding the Serial Number (SN) of the monitoring device to the network.
Navigating to the Plants page and creating a new plant.
Entering basic, system, yield, and owner information for the new plant.
Adding the Gateway/Logger SN to the created plant.
Managing and viewing all created plants on the Plants page.
Accessing the Layout page to edit the physical system layout.
Details of demand response modes supported by the system via RJ-45 connector.
Understanding the different types of export control for PV systems.
Selecting the correct grid type based on geographical location and voltage.
Ensuring CT/Meter range covers system loads and generation.
Wiring instructions for the CHINT DDSU666 Single Phase Meter.
Wiring instructions for CHINT DTSU666 Three Phase Meters (Direct Connect & Via CT).
Connecting the meter to the RS485 port on the monitor device.
Configuring the zero export function on the monitoring platform.
The TSUN Talent-MG2-WP/GP is a monitoring system designed for microinverter installations, acting as a crucial relay station between microinverters and a monitoring server. It facilitates data collection from microinverters and enables remote operation and maintenance through control commands from the server.
The Talent-MG2 monitoring device communicates with microinverters via 2.4G RF wireless technology to gather data and status information. It then connects to the internet, either through Wi-Fi (for Talent-MG2-WP) or GPRS (for Talent-MG2-GP), to exchange this information with the monitoring service. This allows for the transmission of microinverter running data and system status to the monitoring server, and conversely, receives control commands from the server to enable remote management.
The device also supports remote active power control, which is essential in countries requiring generating plants to cease or limit active power output to a regulating level. This is achieved via an RS485 port using the RTU Modbus protocol.
A DRM (Demand Response Mode) function is integrated, supporting various demand response modes (DRM0/5/6/7/8 when used with TSUN microinverters) by connecting an external control device with a standard RJ-45 connector. These modes dictate actions such as operating disconnection devices, not consuming power, limiting power consumption to a percentage of rated power, sourcing/sinking reactive power, not generating power, limiting power generation to a percentage of rated power, and increasing power generation.
Furthermore, the system includes a zero export control function to comply with local grid regulations that limit PV generated power export. This function offers three types: