Overview

The TSUN Talent-MG2-WU/GU is a monitoring system designed for microinverters, specifically the TSOL-M Series. It acts as a key component in the monitoring system, facilitating communication between the microinverters and the Monitoring Server. The device collects data and status from the microinverters via 2.4G RF wireless communication and transmits this information to the internet through Wi-Fi (Talent-MG2-WU) or GPRS (Talent-MG2-GU). This allows for remote operation and maintenance of the microinverter system.

Function Description

The Talent-MG2 monitoring system serves as a bridge, gathering real-time data from individual microinverters and relaying it to a central monitoring server. This enables users to track the performance, status, and any potential issues within their solar power system. The system provides comprehensive information regarding the microinverters and their operational status, allowing for efficient management and troubleshooting.

Important Technical Specifications

The Talent-MG2 series comes in two models: Talent-MG2-WU and Talent-MG2-GU, differing primarily in their communication to the server.

  • Communication to Microinverter:

    • Signal: 2.4G RF
    • Maximum Distance (Open Space): 100m
    • Monitoring Data Limit: 99 panels
  • Communication to Server:

    • Sample Rate: Per 1.5 minutes
    • Signal (Talent-MG2-WU): WiFi (2.4GHz)
    • Signal (Talent-MG2-GU): GSM
  • Power Supply (Adapter):

    • Type: Adapter with USB port
    • Input Voltage/Frequency: 100 to 240V AC / 50 or 60Hz
    • Output Voltage/Current: 5V DC / 2A
    • Power Consumption: 1.0W (typical), 5W (maximum)
  • Mechanical Data:

    • Ambient Temperature: -20 ~ +55 ℃
    • Dimensions (WHD mm): 1433312.5
    • Weight (kg): 0.1
    • Mounting System: Plug-in
    • Indicator Light: LED

Usage Features

The Talent-MG2 monitoring system is designed for straightforward installation and configuration, making it accessible for both qualified technicians and end-users.

  • Installation:

    1. Plug the USB connector into the adapter.
    2. Plug the adapter into a wall socket or a socket on the table. It's important to ensure the wall socket or table is more than 1 meter above the ground, and not metal or concrete to prevent interference with the 2.4G RF signal.
    3. Place the monitoring device at least 90 degrees vertically upwards. The distance between the monitoring device and the router should be as close as possible.
  • Wi-Fi Configuration (Only Talent-MG2-WU):

    1. Connect to the wireless network of MG2-WU via computer or mobile phone.
    2. Open a browser and enter 10.10.100.254 to access the Wi-Fi configuration page. The username and password are 'admin' by default.
    3. Click the Wi-Fi parameter menu on the left menu bar to enter the Wi-Fi parameter configuration.
    4. Search for the desired Wi-Fi network in the lower right corner, select it, and connect to the monitoring device.
    5. Enter the password and click Save.
    6. Click Restart for the changes to take effect.
  • Website Configuration:

    1. Install the microinverter and the monitoring device: Follow the Quick Installation Guide or the User Manual of the microinverter, and connect the power adapter into the socket. Ensure the microinverter system and monitoring device are working correctly.
    2. Establish an account: Visit the monitor website (pro.solarmanpv.com or www.tsun-ess.com) and register a new account.
    3. Networking for the monitoring system:
      • Log in to the platform and navigate to the "Network" page via "Applications".
      • Click "+Select" to input the Serial Number (SN) of the monitoring device.
      • Click "Upload Network Relationship" to download the template file. After editing the file, click "Select a File" to upload it.
    4. Create a Plant:
      • Find the "Plants" page by navigating from "Monitor" to "Plants".
      • Click "Create a Plant" to create a new plant.
      • Input basic information, system information, yield information, and owner information.
      • Click "Save" and add a monitoring device to this plant. Click "Add a New Gateway/Logger" and input the SN of the monitoring device.
      • All plants can be viewed and managed in the "Plants" page.
    5. Edit the system layout:
      • Find the "Plants" page by navigating from "Monitor" to "Plants", then enter the "Layout" page.
      • Click "Click here to edit system layout".
      • Drag the components to the right side to finish the physical layout.
  • LED Description: The device features an LED indicator that provides visual cues about its operational status:

    • Red: Power-on (Alternate Bright 1s), Upgrade procedure (Alternate Shining 1/3s)
    • Blue: Not ID (Bright)
    • Green: Normal operation (Bright), ID search is not complete (Shining), Server not connected (Bright)
    • Red + Blue + Green: Receive server data (Shining)

Maintenance Features

The manual emphasizes the importance of qualified personnel for installation, troubleshooting, and replacement of the monitoring system.

  • Qualified Personnel: Only qualified personnel should install, troubleshoot, or replace the monitoring system.
  • Installation Checks: Before installation, check the unit to ensure absence of any transport or handling damage, which could affect insulation integrity or safety clearances.
  • Repairs: All repairs should be carried out using only qualified spare parts, which must be installed in accordance with their intended use and by a licensed contractor or authorized TSUNESS service representative.
  • Contact Information: For technical problems or product inquiries, users can contact TSUN Service line at +86-573-8466 8569 or email sales@tsun-ess.com. The company address is Building E1, No. 555, Chuangye Road, Dayun Town, Jiashan County, Jiaxing City, Zhejiang Province, China.

TSUNESS Talent-MG2-WU Specifications

General IconGeneral
BrandTSUNESS
ModelTalent-MG2-WU
CategoryMicrophone
LanguageEnglish