EasyManua.ls Logo

TTHERM GEO TVA series User Manual

TTHERM GEO TVA series
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
12/06/2012 GI202
Single and Two-Stage
Packaged Geothermal Heat Pump
Installation & Operating Instructions
Models: TVA/TVT-***
Application
Forced air Geo source installation
Equipped for optional AUX EL strip heat (controller included)
Dual Heat, LMC (load management control), etc. – add option TT-INT
Tested to UL Standards 1995 and CSA Standards C22.2
3-Phase Models
Also see and use GI102
Domestic Water Heater, Desuperheater
Energy Star promotes the desuperheater and it is offered as an optional item for
all TTHERM GEO™ heat pumps. Our exclusive GEO Logic™ control system
optimizes the operation of a desuperheater, operating the systems only when
there is adequate energy available to provide heat to the domestic hot water.
However, to maximize the times the desuperheater aides in providing domestic
hot water, a hot water preheat tank is suggested.
Note
The GEO Logic control board has various required setup adjustments, see Field Setup section.
TTHERM GEO heat pumps leave the factory setup to operate on an open loop. See Open Loop
Solenoid section.
DO NOT DESTROY THIS MANUAL. PLEASE READ CAREFULLY AND KEEP IN A
SAFE PLACE FOR FUTURE REFERENCE BY A SERVICE TECHNICIAN.
Important information
Model Number:____________________________
Serial Number:_____________________________
Installing Contractor:________________________
Question and Answer IconNeed help?

Do you have a question about the TTHERM GEO TVA series and is the answer not in the manual?

TTHERM GEO TVA series Specifications

General IconGeneral
BrandTTHERM GEO
ModelTVA series
CategoryHeat Pump
LanguageEnglish

Summary

TTHERM GEO Unit Introduction

Unit Application and Testing

Describes the unit's applications and testing standards.

Desuperheater for Domestic Hot Water

Details the desuperheater function for domestic hot water.

Unit Handling and Inspection

Moving and Storage Instructions

Provides instructions for storing and moving the unit safely.

Initial Unit Inspection

Outlines steps for inspecting the unit upon receipt.

Unit Location and Mounting Requirements

Specifies requirements for selecting and mounting the unit location.

General Safety and Warnings

Understanding Warnings and Cautions

Explains the meaning of warnings, cautions, and notes in the manual.

Model Number Configuration Guide

Unit Mechanical Specifications

TVT Series Mechanical Details

Details mechanical specifications for TVT two-stage compressor models.

TVA Series Mechanical Details

Unit Electrical Data

TVT/TVA Electrical Ratings and Requirements

Provides electrical data including RLA, LRA, FLA, and fuse requirements.

Ductwork and Blower System

Blower CFM Performance Tables

Lists CFM values for TVT and TVA models under various operating conditions.

Duct Sizing Guidelines

Provides guidelines for sizing branch and main ductwork based on CFM.

Unit Dimensions and Connections

Mechanical Dimension Details

Displays cabinet dimensions and connection sizes for various models.

Electrical and Water Connection Points

Illustrates electrical and water connection points on the unit.

General Installation Requirements

Installation Prerequisites and Safety

Covers essential requirements and safety precautions for installation.

Mechanical Installation Overview

Closed Loop System Installation

Discusses considerations for closed loop geothermal systems, including loop types.

Source Water System Installation

Water Connections and Flow Monitoring

Explains general water piping, P/T ports, and flow meter installation.

Loop Pressure and Water Quality

Details loop pressure requirements and water quality considerations.

Antifreeze and Open Loop Systems

Open Loop System Operation and Maintenance

Describes components and operation for open loop systems.

Water Coil Maintenance Procedures

Addresses maintenance for water coils, especially in open loop systems.

Right Hand Return Conversion

Optional Electric Strip Heat (AUX EL)

Desuperheater for Domestic Hot Water

Desuperheater Plumbing Suggestions

Provides guidance on plumbing the desuperheater and related components.

Condensate Drain System Details

Electrical Installation and Wiring

Wiring, Grounding, and Safety

Covers high voltage wiring, grounding, and safety for electrical installation.

GEO Logic Controller Overview

Controller Applications and Abbreviations

Explains controller features, applications, and defines technical abbreviations.

Available Accessories and Options

Lists available accessories and optional kits for the heat pump system.

Field Setup and Thermostat Wiring

Thermostat and Sensor Wiring

Details thermostat wiring, sensor connections, and requirements.

Loop Configuration and Heat Control

Loop Type Configuration (Jumper J11)

Explains how to configure the unit for open or closed loop operation.

Electric Heat and Desuperheater Activation

Describes how electric heat and desuperheater pumps are activated.

Dual Fuel and Utility Control Options

Details the dual fuel and utility interrupt control options.

Operational Indicators and Front Panel LEDs

Interpreting LED Fault Codes

Interprets the meaning of various LED status indicators for operational faults.

Circuit Board LED Assignments and Status

Shows the location and function of LEDs on the back of the circuit board.

Troubleshooting and Repair Guidance

GEO Logic Controller Troubleshooting Steps

Provides steps for troubleshooting GEO Logic controller issues and general repair tips.

Loop Operation Lockout Causes

Identifies common causes for lockouts in open and closed loop operations.

User Visual Warnings and LED Status

Explains visual warnings indicated by panel LEDs during operation.

Power On Startup Procedures

Operational Tips and System Lockouts

GEO Logic Functions and Lockout Causes

Describes GEO Logic board functions, purge cycles, and lockout scenarios.

ECM Blower Motor Configuration

Pressure Switch and Freeze Protection

Preventive Maintenance Procedures

Air Filter and Water Coil Maintenance

Provides instructions for cleaning air filters and water coils.

Condensate Drain and Blower Motor Care

Covers maintenance for condensate drains and blower motors.

Heating Mode Operating Conditions

Cooling Mode Operating Conditions

General Troubleshooting Guides

Heating and Cooling Troubleshooting Charts

Provides charts to diagnose issues based on system pressures and temperatures.

Relay Board Troubleshooting

Residential Limited Product Warranty

Warranty Conditions and Limitations

Outlines the terms, conditions, and limitations of the product warranty.