Switch on the appliance while keeping the central key pressed for over 1 second.
TUA TRE’ND Face features 5 treatment programs which can be selected by means of the right
arrow key (forward movement) or left arrow key (to move back) each of which is specic
for a face area.
The example shows the program 1
selection procedure specic for the cheek
bone area.
The display shows the number of the
selected program, the total treatment time
expressed in minutes (in this case 3), and
the battery charge, the face icon showing
the area to be treated and the program phase indication.
At this point, the selection procedure ends and treatment can start. To start the program press the
ENTER button.
The intensity of the stimulation current
expressed in milliamperes is indicated
on the display screen on the right. This is
initially set at 00.
By means of the up arrow button and
down arrow button the desired value
can be set (with single step pressures of 1
mA, or by keeping the buttons pressed so forward movement is continuous and faster).
In the example, the value is set at 20 milliamperes.
The progress of the treatment time is indicated by the ashing clock icon and that of the minutes
symbol. The number to the left of the clock symbol represents the selected program work phase.
REGULATING THE INTENSITY
Always remember that individual sensitivity to current can vary considerably and very much
depends on the physiological condition of the person, on perspiration, on the adipose layer, on
the condition of the electrodes and on the level of battery charge.
It is a good idea to increase the impulse level until maximum muscle contraction is achieved with
acceptable current intensity.
The best results can be achieved with deep contractions, but without ever reaching uncomfortable
and troublesome current levels.
The pulses are alternated with intervals; intensity adjustment must only be made during pulses
and not during the intervals to avoid undesired excessive stimulations.
At the end of treatment, switch o TUA TRE’ND by keeping the enter button pressed for
about 2 seconds.
USING THE FACE APPLICATOR
TUA TRE’ND uses a special face applicator consisting of 2 sprung electrodes adjustable in every
direction to be able to adapt to every face conformation.
The stainless-steel electrodes are covered by special cellulose sponges.
Before each treatment, dampen the sponges well using normal tap water and the special spray.
Be very careful: the sponges must be perfectly wet, otherwise they insulate and do not
conduct the pulses.
Do not wet the electrode under the tap. Water could leak inside and remain there for a long
time.
POSITIONING THE FACE APPLICATOR
See section FACE APPLICATIONS (positioning of electrodes).