What causes a pressure drop on the manometer (k2) or repeated blocking of the S-valve in Turbosol Construction Equipment?
T
Taylor SinghSep 16, 2025
A pressure drop or repeated blocking of the S-valve indicates play between the S-valve and the wear plate. Adjust the S-valve.
K
Kristie WyattAug 25, 2025
Why does the diesel engine work irregularly and tend to switch off in my Turbosol Beton Master?
S
Sarah EricksonAug 25, 2025
An irregularly working diesel engine that tends to switch off in your Turbosol Construction Equipment can be due to several factors:
* Clogged diesel oil filters: Replace the diesel oil filters.
* Faulty manual pump: Replace the manual pump.
* Low diesel oil level: Add diesel oil.
* Clogged air filters: Clean or replace the air filters.
A
Abigail GarciaAug 25, 2025
What to do if the water temperature alarm is on and the diesel engine switches off in my Turbosol Beton Master Construction Equipment?
L
Lori WilsonAug 26, 2025
If the water temperature alarm activates and the diesel engine shuts down on your Turbosol Construction Equipment, it could be due to: insufficient cooling liquid level or a dirty engine cooling radiator. In this case, top-up the cooling liquid level and clean the radiator. It may also be caused by a faulty water pump, which would then need to be replaced.
M
Malik WilliamsAug 26, 2025
What to do if the starter motor turns but the diesel engine does not start on my Turbosol Beton Master Construction Equipment?
B
Bradley WardAug 27, 2025
If the starter motor turns but the diesel engine doesn't start on your Turbosol Construction Equipment, first check if the fuel tank is empty and fill it if necessary. If there is fuel, check if the fuel is reaching the engine by checking the diesel oil solenoid valve control relay operation. Also, pump fuel using the manual pump and ensure the manual pump is not broken.
W
Wendy SmithSep 18, 2025
Why is there dirty water in the pistons cooling tank of my Turbosol Construction Equipment?
L
Laura DavisSep 18, 2025
Dirty water in the pistons cooling tank is caused by worn pumping pistons. Replace the pumping pistons.
S
smonroeSep 23, 2025
What causes no balancing in my Turbosol Beton Master Construction Equipment?
A
Andrea EscobarSep 23, 2025
No balancing is caused by a gas spring that is weakened or faulty. Replace the gas spring.
A
albert70Sep 8, 2025
Why is the parking brake not very efficient on my Turbosol Beton Master Construction Equipment?
A
Andrea YuSep 8, 2025
The parking brake might not be very efficient due to incorrect calibration or too much play in the tie-rods. The brake linings might not be run-in, which should resolve itself. There could also be too much friction between the mobile components, so ensure all transmission parts and tie-rods run well and are lubricated. Also, the gas spring could be faulty and need replacement.
M
mark57Sep 9, 2025
What to do if the mixer does not turn in my Turbosol Beton Master?
R
robert04Sep 9, 2025
If the mixer does not turn, first check if the function is active on the control panel by pressing the button (e1). Also, check if the hopper grid is open and close it. There might be a foreign body blocking the mixer, so remove it. Finally, there could be a breakdown of the mixer control electrovalve, so check its wiring and the relative relay.
J
Joshua WhiteheadSep 3, 2025
Why does the diesel engine in my Turbosol Construction Equipment function irregularly and tend to switch off?
S
shellyjamesSep 3, 2025
The diesel engine might function irregularly and tend to switch off due to several reasons. The diesel filters could be blocked, requiring replacement. The reserve diesel tank might be empty, needing a refill. Alternatively, the air filters could be blocked, requiring cleaning or replacement.
B
bjacksonSep 1, 2025
What to do if my Turbosol Construction Equipment does not pre-heat spark plugs upon start-up?
S
smarquezSep 1, 2025
If your Turbosol Construction Equipment isn't pre-heating the spark plugs upon start-up, it's likely due to a faulty spark plugs pre-heat relay. Check the spark plugs pre-heat relay operation and replace it if required.