Controls
The MAYFAIR is controlled via the actuator which,
being non-electric, can be situated close to the taps or
wherever is most convenient, it is not to be used, though,
as a footswitch. The green light indicates that the unit is
operating. A red light indicates that the motor has been
overloaded and has cut out.
The CHELSEA, VICTORIA, KENSINGTON, & 125
models are controlled by a double-pole fused spur switch
(not supplied) on the wall, or optional air switch.
The CHELSEA PLUS is controlled by an air switch.
Reversing
Both the MAYFAIR and the CHELSEA are
automatically self-reversing: should a minor jam occur the
machine will instantly operate in the opposite direction
to help reduce jamming. This feature also ensures equal
wear on both sides of the cutter ring.
If a foreign object accidentally falls into the unit:
1. Switch off the machine immediately.
2. Switch off the machine at the mains.
3. Push the release key through the splashguard
and engage it on the impellor ns. Turn the
handle in either direction until the impellor
rotates freely, and remove the release key.
Remove any foreign objects.
4. Press the Reset button (Overload Protector).
5. Switch on the power and restart the Tweeny.
Should the disposer still fail to operate, call
01424 751888 for assistance.
Seal failure for Mayfair and Chelsea
Warning of seal failure is given by water seepage through
the bleedhole opposite the outlet elbow. In this event
call Tweeny 01424 751888.
In the event of a power cut
Switch off the disposer at the mains.