12
Electrical installation
The fuse to be tted must be of a 10A rating.
This appliance must be installed in accordance with IEE regulations.
The unit must be connected to the supply by means of a non-detachable exible cord or by wires in a
exible conduit and means for disconnection must be incorporated in the xed wiring having a contact
separation of at least 3mm in all poles. When installing the unit, care must be taken that the overload reset
button remains readily accessible.
Warning: The unit must be earthed.
The wires in this mains lead are coloured in accordance with the following code:
Green and yellow: Earth
Blue: Neutral
Brown: Live
As the colours of the wires in the mains lead of the unit may not correspond with the coloured markings
identifying the terminals in the double-pole fused spur switch proceed as follows:
-The wire which is coloured green-and-yellow must be connected to the terminal in the switch which is
marked with the letter ‘E’ or by the earth symbol or coloured green or green-and-yellow.
-The wire which is coloured blue must be connected to the terminal which is marked with the letter
‘N’ or coloured black.
-The wire which is coloured brown must be connected to the terminal which is marked with the letter
‘L’ or coloured red.
If the supply cord of this appliance is damaged it must only be replaced by the manufacturer or one of the
manufacturer’s Authorised Service Agents. Before starting the unit for the rst time ensure that there are
no foreign objects in the grinding chamber and that there is an adequate supply of water owing through
the unit when it is switched on.