Ifyourdesiredinjectionratesrequireasettingthatexceeds4(Cycles)and3(Duration),additionalpowermayberequired.
SPC1000OperationInstructions
Setup Instructions
Step 1
Connect the battery positive and negative terminals as indicated (+POWER-) on the controller.
Step 2
Connect the pump motor to the positive and negative terminals as indicated (-MOTOR+) on the controller.
Step 3 (Optional)
If using a Temperature Probe, it may be connected at any time. If a probe is connected temperature control will
be active. If no probe is connected, temperature control is not used.
Step 4
Flip the toggle from the OFF position to the RUN position to begin pumping.
Step 5
OPTIONAL MODE SELECTION – Once you have flipped the toggle to the RUN position, you may hold the
rotary knob down until the screen alternates between modes. The available mode options are as follows:
Cycles per Minute Mode: Cycles = 1-10, Duration = 0.5 to 5.5
On Time Mode: 0.5 seconds to 5.5 seconds-half second increments
Temperature Mode: 30*F-90*F
Remote Input Mode: 4-20mA
Modbus Mode: RS-485
NOTE: The default settings are in Cycles per Minute which are half seconds.
*Battery voltage must be above 10 volts for operation. The battery display will show when the battery is too low for pump operation.