Ifyourdesiredinjectionratesrequireasettingthatexceeds4(Cycles)and3(Duration),additionalpowermayberequired.
SPC1000OperationInstructions
Setup Instructions
Step 1
Connect the battery positive and negative terminals as indicated (+POWER-) on the controller.
Step 2
Connect the pump motor to the positive and negative terminals as indicated (-MOTOR+) on the controller.
Step 3 (Optional)
If using a Temperature Probe, it may be connected at any time. If a probe is connected temperature control will
be active. If no probe is connected, temperature control is not used.
Step 4
Flip the toggle from the OFF position to the RUN position to begin pumping.
Step 5
OPTIONAL MODE SELECTION – Once you have flipped the toggle to the RUN position, you may hold the
rotary knob down until the screen alternates between modes. The available mode options are as follows:
Cycles per Minute Mode: Cycles = 1-10, Duration = 0.5 to 5.5
On Time Mode: 0.5 seconds to 5.5 seconds-half second increments
Temperature Mode: 30*F-90*F
Remote Input Mode: 4-20mA
Modbus Mode: RS-485
NOTE: The default settings are in Cycles per Minute which are half seconds.
*Battery voltage must be above 10 volts for operation. The battery display will show when the battery is too low for pump operation.

Other manuals for TXAM Pumps SPC1000

Question and Answer IconNeed help?

Do you have a question about the TXAM Pumps SPC1000 and is the answer not in the manual?

TXAM Pumps SPC1000 Specifications

General IconGeneral
CategoryController
ModelSPC1000
Protection ClassIP65
Dimensions150 x 100 x 50 mm
Weight0.5 kg
Output Current10A
Operating Temperature-10°C to +50°C