Version 4.10 TSM/Kli 05.03.2017
© Copyright tyco Fire Protection Products Doc: 3-052-011d
INSTALLATION INSTRUCTIONS
FAST2000
®
/2
19”-Rack Version
Fire Detection and
Extinguishing Control System

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Tyco Fire Protection Products FAST2000/2 and is the answer not in the manual?

Summary

1 Introduction

1.1 Safety

Safety precautions for the FAST2000/2 system, power supply, and battery usage.

1.2 Warranties and Constraints

Warranty limitations and constraints regarding unauthorized repairs or modifications.

2 Description and structure

2.1 Mechanical structure

Details the 19" modular system design, rack configurations, and module placement.

2.1.1 19” Rack

Describes standard 19" racks for modules, including height and width.

2.2 Electrical Connections

Explains connections via 64-pin Euro connectors, ribbon cables, and 10-pin connectors for modules.

2.3 Power Supply

Details system power from mains and batteries, including monitoring circuits.

2.4 Detection Loops

Explains connection to loop modules and protocols used.

2.4.1 System Sensor Loop Devices

Lists System Sensor devices, addressing, and analogue detector behavior.

2.4.1.1 Automatic System Sensor loop devices

Lists automatic System Sensor loop devices.

2.4.1.2 Non-automatic System Sensor loop devices

Lists non-automatic System Sensor loop devices.

2.4.2 Tyco Loop Devices

Lists Tyco MZX series loop devices and their addressing.

2.4.2.1 Automatic Tyco MZX loop devices

Lists automatic Tyco MZX loop devices.

2.4.2.2 Non-automatic Tyco MZX loop devices

Lists non-automatic Tyco MZX loop devices.

2.4.3 Detection Circuit Operation

Explains typical loop configuration and continuity checks.

2.4.4 Scanning the Detection Loops

Details loop scanning and scan time calculation.

2.4.5 Downloading Type Information to LM-Module

Explains downloading device type info for loop modules.

2.4.6 Scan Time Calculation

Provides formula and example for calculating scan times.

2.5 Extinguishing

Introduces modules dedicated to extinguishing systems.

2.5.1 Extinguishing Conditions

Describes conditions for gas release and time delays.

2.5.2 Extinguishing-Stop (Emergency Hold)

Explains the "Hold"-input function for emergency stop.

3 The Modules of the FAST2000;2

CM-32;2 Control module

Details the main intelligent module handling monitoring and control.

CM-32 T Power supply supervisory module (up to 2012)

Monitors power supply and batteries.

CM-32 T;2 Power supply supervisory module (since 2013)

Monitors power supply and batteries.

CM-32 F Fire brigade termination board (up to 2008)

Interface board for German fire brigade panels.

CM-32 F;2 Fire brigade termination board (since 2009)

Updated interface board for German fire brigade panels.

CM-32 R Common relay termination board

Board providing relays for system status reporting.

CM-32 P RS-232 interface card for printer connection

Interface card for connecting printers.

PM-32 Power converter module

Module delivering 8V DC power to other modules.

DM-32;2 Display module

Man-machine interface module with LCD display.

DP-157 Power Supply (up to 2008)

Power supply unit used until 2008.

ADC 5483 Power Supply (since 2008)

Power supply unit used since 2008.

LM-32 TX Loop module for Tyco detectors

Loop module for Tyco detectors.

LM-32 TXT Termination board for LM-32 TX

Termination board for the LM-32TX module.

LM-32 D Loop module detection area

Loop module for detection areas.

LM-32 DT Detection area termination board

Termination board for detection areas.

LM-32 E Loop module for extinguishing area

Loop module for extinguishing areas.

LM-32 ET Extinguishing area termination board

Termination board for extinguishing areas.

AM-32 Alarm monitoring for stepper motor systems

Module for monitoring stepper motor systems.

EM-32 Extinguishing module

Module for supervising and controlling extinguishing agent storage.

EM-32 T Extinguishing module termination board I

Termination board with one output and inputs.

EM-32 TER Extinguishing module termination board II

Termination board with two outputs and inputs.

EM-32 STE Extinguishing module termination board III

Termination board with stepper motor output.

IO-32 Input;output module

Interface unit for processor units and output cards.

IO-32 T Relay output termination board

Relay output termination board.

IO-32 TOC Open collector output termination board

Open collector output termination board.

ZI-32 Zonal indication module

Module providing zone indication for alarms and faults.

RM-32 Revision module with 2 key switches

Module for overriding tripping functions.

CM-32 CTCB2 Communication termination board 2

Board for communication between panels.

CM-32 CTCM422 RS422 termination board

Board for converting CM-32 serial to RS422/RS485.

CM-32 CTCM232 RS232 termination board

Board for converting CM-32 serial to RS232.

CM-32 CTCM1 30 mA termination board

Board for converting CM-32 serial to Signalco 30mA.

CM-32 CTOPT1 Fibre optic termination board

Board for converting CM-32 serial to fibre optic signals.

IM-32 RS232 interface card

RS232 interface card.

3.1 CM-32;2 Control Module

LED FIRE BRIGADE

Explains the yellow LED indicating faults or isolation of the fire brigade circuit.

LED BELL

Explains the yellow LED indicating faults or isolation of alarm bell circuits.

LED POWER FAULT

Explains the yellow LED indicating power supply faults.

Available CM-32 terminal boards

Lists available terminal boards for the CM-32.

3.1.1 Circuit Description

Provides block diagram of CM-32/2 and lists LED functions/colors.

3.1.2 Electrical Connections

Describes connectors for external cards and modules on CM-32.

3.1.3 Jumper Settings

Details jumper settings for boot device, mode config, and serial ports.

3.1.4 Technical Data

Lists supply voltage, current consumption, and dimensions for CM-32.

3.2 CM-32 T Power supply supervisory module

3.2.1 Circuit Description

Details card's connections and 24V outputs.

3.2.2 Pin - Configuration

Shows pin configurations for terminal block J1 and connector J2.

3.2.3 Fuse Information

Specifies fuse data for CM-32T module.

3.2.4 Electrical and mechanical Data

Lists voltage output, current consumption, and dimensions.

3.3 CM-32 T;2 Power supply supervisory module (since 2013)

3.3.1 Circuit Description

Describes card's connections and power source switching.

3.3.2 DIP Switch S1

Explains DIP switch S1 function for CM-32T2 setup.

3.3.3 LED- indications

Details LED indicators for system status on CM-32T/2.

3.3.4 Klemmenbelegung

Shows terminal block J1 and relevant pins on header J2.

3.3.5 Fuse Information

Specifies fuse data for CM-32T/2.

3.3.6 Technical Data

Lists input voltage, output voltage, current, battery type, and dimensions.

3.4 CM-32 F Fire Brigade Termination Board (until 2008)

3.4.1 Circuit Description

Details pin configurations for terminal blocks J1 and J2.

3.4.2 Fuse Information

Specifies fuse data for CM-32F.

3.4.3 Technical Data

Lists operating voltage, current consumption, and dimensions.

3.5 CM-32 F;2 Fire Brigade Termination Board (since2009)

3.5.1 Circuit Description

Shows pin configurations for terminal blocks J3 and J2.

3.5.2 Fuse information

Specifies fuse data for CM-32F/2.

3.5.3 Technical Data

Lists operating voltage, current consumption, and dimensions.

3.6 CM-32 R Common Relay Termination Board

3.6.1 Circuit Description

Explains the function of output relays and monitored fault output.

3.6.2 Electrical Connections

Details pin configurations for terminal block J1 and ribbon cable connector.

3.6.3 Technical Data

Lists operating voltage, current consumption, and relay ratings.

3.7 CM-32 P RS232 Interface card for Printer Connection

3.8 PM-32 Power Converter Module

3.8.1 Inputs and Outputs

Outlines the inputs and outputs of the PM-32 module.

3.8.2 Electrical Connections

Describes module's connectors and optional power source.

3.8.3 Technical Data

Lists supply voltage, current consumption, and dimensions.

3.9 DM-32;2 Display Module

3.9.1 ELECTRICAL CONNECTIONS

Lists connectors for external cards and modules.

3.9.2 TECHNICAL DATA

Lists supply voltage, current consumption, and dimensions.

3.10 Power supply unit ADC 5483

3.11 LM-32 TX Loop-Module Extinguishing for

3.11.1 Setting of Module address

Explains setting LM-32TX module's address via software.

3.11.2 Circuit description

Details module's electronics, MCU, memory, interfaces, and power.

3.11.3 Electrical Connections

Explains external connections via 64-pin edge connector.

3.11.4 64-pin Edge Connector Pin-out

Refers to chapter 9 for signals on LM-32D connector.

3.11.5 Electrical and mechanical Data

Lists supply voltage, current consumption, and dimensions.

3.12 LM-32 TXT Extinguishing Area Termination Board for Tyco Loop Devices

3.12.1 Electrical Connections

Outlines connection points for LM-32TXT.

3.12.1.1 Detection Circuits

Details detection circuit connections, length, resistance, capacitance.

3.12.1.2 Auxiliary Inputs

Explains ten auxiliary inputs for monitoring extinguishing systems.

3.12.1.3 Sounder; Bell output 1-2

Describes terminals for two monitored sounder outputs.

3.12.1.4 Valve; Solenoid Output 3 + 4

Explains outputs for controlling valves with monitoring.

3.12.1.5 24 V Power supply connection

Details 24V power supply connection points.

3.12.1.6 The Ribbon Cable Connection

Describes connection between LM-32TXT and LM-32TX.

3.12.2 LED Indications

Details LED indicators for status and communication.

3.12.3 Fuse Information

Specifies fuse data for sounder outputs.

3.13 LM-32 D Loop Module Detection

3.13.1 Setting the Card-Address

Explains setting LM-32D card address using DIP switch.

3.13.2 Circuit Description

Block diagram of LM-32D and its interaction with modules.

3.13.3 Electrical Connections

Details external connections via 64-pin connector and LED board.

3.13.4 64-pin Edge Connector Pin-out

Refers to appendix A for LM-32D connector signals.

3.13.5 Electrical and mechanical Data

Lists supply voltage, current consumption, and dimensions.

3.14 LM-32 DT Detection Area Termination Board

3.14.1 Electrical Connections

Outlines connection points for LM-32DT.

3.14.1.1 Detection Circuits

Details detection circuit connections, length, resistance, capacitance.

3.14.1.2 Auxiliary Inputs

Explains three auxiliary inputs for input monitoring.

3.14.1.3 Sounder Outputs (Alarm Bell Circuits)

Describes terminals for two monitored sounder outputs.

3.14.1.4 The 24 V Connection Points

Details 24V power supply connection points.

3.14.1.5 The Ribbon Cable Connection

Describes connection between LM-32DT and LM-32D.

3.14.2 Fuse Information

Specifies fuse data for sounder outputs.

3.14.3 Electrical and mechanical Data

Lists voltage, current consumption, and dimensions.

3.15 LM-32 E Loop Module Extinguishing

3.15.1 Setting the Card-Address

Explains setting LM-32E card address using DIP switch.

3.15.2 Circuit Description

Block diagram of LM-32E and its power supply.

3.15.3 64-pin Edge Connector Pin-out

Refers to appendix A for LM-32D connector signals.

3.15.4 Electrical and mechanical Data

Lists supply voltage, current consumption, and dimensions.

3.16 LM-32 ET Extinguishing Area Termination Board

3.16.1 Electrical Connections

Outlines connection points for LM-32ET.

3.16.1.1 Detection Circuits

Details detection circuit connections, length, resistance, capacitance.

3.16.1.2 Auxiliary Inputs

Explains six auxiliary inputs for input monitoring.

3.16.1.3 Sounder Outputs (Alarm Bell Circuits)

Describes terminals for two monitored sounder outputs.

3.16.1.4 Valve Outputs

Explains valve outputs for controlling zone and CO2 stop valves.

3.16.1.5 The 24 V Connection Points

Details 24V power supply connection points.

3.16.1.6 The Ribbon Cable Connection

Describes connection between LM-32ET and LM-32E.

3.16.2 Fuse Information

Specifies fuse data for sounder outputs.

3.16.3 Electrical and mechanical Data

Lists voltage, current consumption, and dimensions.

3.17 LM-32 SCT Ext. Area Termination Board with Stepper Motor Output

3.17.1 Electrical Connections

Outlines connection points for LM-32SCT.

3.17.1.1 Detection Circuits

Details detection circuit connections, length, resistance, capacitance.

3.17.1.2 Auxiliary Inputs

Explains six auxiliary inputs for input monitoring.

3.17.1.3 Sounder Outputs (Alarm Bell Circuits)

Describes terminals for two monitored sounder outputs.

3.17.1.4 Valve Outputs

Explains valve outputs for controlling zone and CO2 stop valves.

3.17.1.5 The 24 V Connection Points

Details 24V power supply connection points.

3.17.1.6 The Ribbon Cable Connection

Describes connection between LM-32SCT and LM-32E.

3.17.2 Fuse Information

Specifies fuse data for sounder outputs.

3.17.3 Electrical and mechanical Data

Lists voltage, current consumption, and dimensions.

3.18 AM-32 Alarm Monitoring for Stepper Motor Systems

3.19 EM-32 Extinguishing Module

3.20 EM-32 T Extinguishing Module Termination Board I

3.21 EM-32 TER Extinguishing Module Termination Board II

3.22 EM-32 SCT Ext. Module Termination Board III with Stepper Motor Output

3.23 IO-32 Input;Output Module

3.23.1 Inputs and Outputs

Explains data shifting and port configuration.

3.23.2 Circuit Description

Details regulator circuit, shift registers, and driver.

3.23.3 User Set-Up

Explains how IO-32 card is controlled by LM-32D/E or CM-32.

3.23.4 Electrical Connections

Details 64-pin Euro connector and 26-pin connector for modules.

3.23.5 Electrical and mechanical Data

Lists PCB dimensions, supply voltage, and current consumption.

3.24 IO-32 T Output Termination Board

3.24.3 Corresponding Set-Up´s IO-32 T

Explains accessing relays via lines based on jumper settings.

3.24.4 Ribbon Cable Connectors J1 and J2

Shows pin configurations for ribbon cable connectors.

3.24.5 Terminal Block Connections

Lists terminal block connections for relays.

3.24.6 Electrical and mechanical Data

Lists supply voltage range.

3.25 IO-32 TOC Input;Output Termination Board Open Collector

3.25.1 Terminal Block Connections

Lists terminal block connections for outputs.

3.26 ZI-32 Zone Indication Module

3.27 RM-32 Revision Module

3.28 Communication termination board, CM-32 CTCB2

3.28.1 ELECTRICAL CONNECTIONS

Outlines connection points for CM-32CTCB2.

3.28.1.1 Power terminal block J4

Details power terminal block J4 for 24V supply.

3.28.1.2 The ribbon cable connector J3

Describes ribbon cable connection to CM-32 serial channels.

3.28.1.3 Driver module connectors J1-J2

Details driver module connectors J1 and J2.

3.28.2 JUMPER SETTINGS

Details jumper block LK1 for selecting driver board connections.

3.29 CM-32 CTCM422 RS422 termination board

3.29.1 ELECTRICAL CONNECTIONS

Outlines connection points for CM-32CTCM422.

3.29.2 Driver module connector J1

Details driver module connector J1.

3.29.3 RS422;RS485 terminal block J2

Explains terminal block J2 for RS422/RS485 connections.

3.29.4 LEDs

Describes LEDs indicating serial channel activity.

3.29.5 JUMPER SETTINGS

Details jumper block LK1 for break signal transmission.

3.29.6 TECHNICAL DATA

Lists input voltage, current consumption, resistor, and dimensions.

3.30 CM-32 CTCM232 RS232 termination board

3.30.1 ELECTRICAL CONNECTIONS

Outlines connection points for CM-32CTCM232.

3.30.2 Driver module connector J1

Details driver module connector J1.

3.30.3 RS232 terminal block J2

Explains terminal block J2 for RS232 signal levels.

3.30.4 RS232 ribbon cable connector J3

Details ribbon cable connector J3 for RS232 signals.

3.30.5 LEDs

Describes four LEDs indicating serial channel traffic.

3.30.6 JUMPER SETTINGS

Details jumper block LK1 for break signal transmission.

3.30.7 TECHNICAL DATA

Lists input voltage, current consumption, and PCB dimensions.

3.31 CM-32 CTCM1 30 mA termination board

3.31.1 ELECTRICAL CONNECTIONS

Outlines connection points for CM-32CTCM1.

3.31.2 Driver module connector J1

Details driver module connector J1.

3.31.3 30 mA terminal block J2

Explains terminal block J2 for Signalco 30mA communication.

3.31.4 LEDs

Describes two LEDs indicating serial channel traffic.

3.31.5 JUMPER SETTINGS

Details jumper blocks LK1 for monitoring and LK2 for 30mA driver.

3.31.6 TECHNICAL DATA

Lists input voltage, current consumption, and PCB dimensions.

3.32 CM-32 CTOPT1 Fibre optic termination board

3.32.1 ELECTRICAL;OPTICAL CONNECTIONS

Outlines connection points for CM-32CTOPT1.

3.32.2 Driver module connector J1

Details driver module connector J1.

3.32.3 Fibre optic connectors U1-U2

Describes fibre optic connectors for cable connection.

3.32.4 LEDs

Describes two LEDs indicating RX and TX traffic.

3.32.5 Jumper Settings

Details jumper blocks LK1 and LK2 for current adjustment and break signal.

3.32.6 Technical Data

Lists PCB dimensions and cable specifications.

4 Installation

4.1 General

Emphasizes following installation drawings and local codes.

4.1.1 Mechanical Installation

States mechanical installation must follow site-specific drawings.

4.1.2 Electrical Installation

Details electrical installation requirements, cable connections, and earthing.

4.2 Power and Battery Supply

Explains system power supply, battery supervision, and cable connections.

4.3 Detection Circuits

Describes loop connection to LM-32DT/LM-32ET, noting polarization.

4.4 Auxiliary Inputs

Details auxiliary inputs for monitoring signals.

4.5 Sounder Outputs

Describes terminals for two monitored sounder outputs.

4.6 Dedicated Relays

Explains four output relays on CM-32R for system status reporting.

4.7 Relay Connections

Details how relays are controlled by Cause & Effect.

4.8 Valve Outputs

Explains valve outputs with open/short circuit monitoring.

4.9 Fire Brigade-Interface

Describes standard inputs/outputs for fire brigade panels using CM-32F.

4.10 Printer and RS-232 Interface

Details the CM-32P RS-232 interface card.

5 Commissioning

5.1 Detection Loops

States detection circuits must always be configured as loops.

5.2 Outputs

Advises disconnecting output devices during testing.

5.3 Inputs

Advises disconnecting inputs after testing.

5.4 Record Keeping

Emphasizes keeping detailed records of hardware and software configurations.

5.5 Power Up

Describes the procedure for powering up the system.

5.6 The Charger

Details connecting and switching on the charger, checking indicators.

5.6.1 The Battery

Explains battery cut-off relay function and testing.

5.7 Commissioning of the Loops

Outlines loop commissioning, including wiring and electrical checks.

5.7.1 Wiring Checks

Details visual checks, loop resistance, and continuity tests.

5.7.2 Electrical Checks

Describes electrical checks, simulating faults, and verifying readings.

5.7.3 Connecting the Sounder Outputs

Provides procedure for connecting and testing sounder outputs.

5.8 Connecting the dedicated Control-Relays

Explains connecting and testing dedicated control relays.

5.9 Connecting the Fault Output

Details procedure for checking fault output connection.

5.10 Zone Valve Output

Outlines procedure for checking zone valve output connection.

5.11 Connecting the Control-Relay Outputs

Provides procedure to check and connect control relay outputs.

5.12 Dedicated Auxiliary Inputs

Details how to test auxiliary inputs.

5.13 Fire-Brigade Panel

Describes checks for the fire brigade panel interface.

5.14 RS-232 Interface and Printer Connection

Advises on connecting RS-232 equipment.

5.15 System Initiating

Outlines the procedure for initiating the panel.

5.16 Complete System Test

Describes performing a complete system test after commissioning.

6 Fault Finding

6.1 Automatic Monitoring

Explains system self-monitoring for power, circuits, and microprocessors.

6.1.1 False Alarm Reduction

Details automatic signal level comparison for false alarm reduction.

6.1.2 Fault Alarms

Explains how fault alarms are displayed and how to get more information.

6.2 System Data

Mentions system information sources.

6.2.1 Trouble Shooting

Provides guidance on a methodical approach to finding and correcting faults.

6.2.2 The Display-Module DM-32 is Dead

Lists symptoms, causes, and actions for a non-functional DM-32.

6.2.3 The Control-Module CM-32 is Dead

Lists symptoms, causes, and actions for a non-functional CM-32.

6.2.4 Power Supply Failure

Lists symptoms, causes, and actions for power supply failures.

6.2.5 Open Circuit on the Alarm Bell Circuit

Describes symptoms, causes, and troubleshooting for alarm bell open circuits.

6.2.6 Short Circuit on the Alarm Bell Circuit

Describes symptoms, causes, and troubleshooting for alarm bell short circuits.

6.2.7 Open Circuit on Detection Loops

Details symptoms, causes, and troubleshooting for detection loop open circuits.

6.2.8 Short Circuit on Detection Loop

Details symptoms, causes, and troubleshooting for detection loop short circuits.

6.2.9 Earth Fault

Describes symptoms, causes, and troubleshooting steps for earth faults.

7 Service and Maintenance

7.1 Maintenance Program

Recommends a scheduled service and maintenance program.

7.2 The Main Service

Outlines the purpose of the main service, recommending it annually.

7.2.1 Main Service of the Man;Machine Interface

Details checks for front panel, keys, display, and indicators.

7.2.2 Visual Inspection of the Panel

Describes visual checks of enclosures, wiring, terminals, fuses, PCBs.

7.2.3 Main Service of the Power Supply

Details checking charger output voltage and battery voltage.

7.2.4 Checking the Communication Bus

Explains checking communication bus activity and voltage.

7.2.5 Main Service of the Detection Loops

Details checking zoning, device types, and loop continuity.

7.2.6 Main Service of Sounder Loops

Describes checking sounder circuits for faults and alarm conditions.

7.2.7 Checking the Control-Relays

Details simulating activation conditions to check relay operation.

7.2.9 Checking the Auxiliary Inputs

Describes checking auxiliary inputs and panel actions.

7.2.10 Checking the Fire Brigade Panel

Details testing fire brigade panel activation and reset.

7.3 The Minor Service

Explains the purpose of minor service, recommending it bi-monthly.

7.3.1 Minor Service of the Man;Machine Interface

Lists checks for front panel, keys, display, and switches.

7.3.2 Minor Service of the Power Supply

Details checks for charger voltage, battery voltage, and fault reporting.

7.3.3 Minor Service of the Detection Loops

Describes checking devices for faults and testing selected devices.

7.3.4 Minor Service of the Sounder Circuits

Details simulating alarm conditions to check sounder operation.

7.3.5 Checking the Calling Equipment

Describes checking signal transmission to calling equipment.

8 Appendix A: The Default Program

8.1 Fault Alarm Inputs

Explains the default response to a fault alarm.

8.2 Fire Alarm Inputs

Details default actions for fire alarm inputs.

8.3 Prewarnings

States no default response to prewarnings.

8.4 General Auxiliary Inputs

Notes auxiliary inputs are not used by default unless custom programmed.

9 Signals on 64-pin connector

9.1 Signals on connector of CM-32

Provides a detailed breakdown of signals on the CM-32's 64-pin connector.

9.2 Signals on connector of LM-32

Lists signals on the LM-32's 64-pin connector.

9.3 Signals on connector of EM-32

Lists signals on the EM-32's 64-pin connector.

9.4 Signals on connector of IO-32

Lists signals on the IO-32's 64-pin connector.

10 Address setting with DIP-Switches on LM- and EM-Module

11 Service Functions

12 Wire Resistance Considerations

13 Analogue Values

14 Ordering the Dummy Plates

15 FAST2000 Loop Loading and Battery Calculations

15.1 Introduction

Introduces loop loading parameters and calculation methods.

15.2 Short-circuit isolators

Discusses the use and purpose of short-circuit line isolators.

15.3 Loop loading

Explains maximum addressable units and permissible loading.

15.4 LPS800 loop powered sounder module loop loading considerations

Discusses considerations for LPS800 modules regarding operating range.

15.5 Cable type and cable length

Covers cable requirements, types, and length for MX Digital Loops.

15.5.1 General

States cable requirements must meet local standards.

15.5.2 Cable types

Lists various fire-resistant cable types.

15.5.3 Cable length

Provides guidelines for cable lengths.

15.5.4 Cable screen

Discusses the importance of cable screens.

15.6 Voltage drop

Explains voltage drop calculations.

15.7 Calculation sheets

Refers to pages 8-12 for calculation sheets.

15.7.1 Loop Loading Calculation Sheet Per Loop

Provides a sheet for calculating loop loading per loop.

15.7.2 Loading Between Line Isolators Calculation Sheet

Provides a sheet for calculating load between line isolators.

16 MZX-Melder, Störungscodes

17 Revision History