User Manual
To Our Valued Customers
Name of the each part of the product
Package Contents
The scale remover is designed to remove the scale inside of the water
ionizer. It is very important to handle this device with care in order to
properly descale and avoid malfunctions of the water ionizer. Please
read the following warnings carefully before using the device.
This device must be kept out of the reach of children
and must not be used by children without supervision.
Safety Precautions and Warnings
DO NOT USE any other substances other than the citric acid
provided by TYENT.
DO NOT DRINK the citric acid or citric acid water.
Keep the device out of reach of children
The method of using the scale remover for each water ionizer
model is different, so please read the user manual thoroughly
before using the device.
If the water outlet of the water ionizer is blocked due to scale,
the scale remover automatically stops or the connections may
be seperated due to internal pressure (Please contact the
service center)
If citric acid or scale substance remain in the scale remover
after use, it may cause malfunctions. Be sure to remove the
citric acid and scale substance thoroughly before storing.
Do not use on the wet floor.
If placing the device on the sink, dry the floor before use.
Place the product on a flat surface to operate.
Do not use the device for more than 30 minutes continuously.
Do not spray water on the outside of device. It may cause
malfunctions.
Thank you for purchasing TYENT Scale remover. This device is for
scale removal and management that may be accumulated inside of
the water ionizer. Be sure to read this manual and use the product
correctly before using the scale remover.
Check the components after opening the package. Components are
subject to change in specification without prior notice in order to
improve the product performance.
Device
ø7 Connecting hose
ø10 Gender
Combined hose 2EA
*For UCE-PLUS only (see How to use)
*Use for direct connection to the
Drain hose (refer to “How to use)
Read the manual before using and
cut it into appropriate length
Citric acid(25g)
4EA
Skimming filter
5EA
How to use
DO NOT
operate the water ionizer while using the scale
remover.
For effective scale removal, the pump turns on/off automatically
repeated for 10 minutes.
The pump operation sounds repeat on/off. It is not a malfunction.
If the connecting hose is blocked because of twisting during operation,
the device stops operation by the battery voltage.
Top cover
Inlet connection
Operation lamp
Operation button
Battery cover
Connect with Drain
Outlet connection
Connect with
alkaline water outlet
Bottom
LED’s on when device operates
908, Ungsang-daero, Yangsan-si, Gyeongsangnam-do, Korea
TEL 82.55.363.6670
E-mail. info@tyentgroup.com
MADE IN KOREA
www.tyentgroup.com
ø10
5/16″- 7/16″
1/4- 3/8 Connector
If the device is used in a humid place, it may cause the product failure.
Please do not use rechargeable batterie
s, be sure to use
1.5v Alkaline battery.
Remove the battery cover at the bottom and install the Battery(AA).
(After place the battery, be sure to close the battery cover.)
Check the filter is fixed inside of the scale remover.
Check the power plug of water ionizer before operating the scale remover.
Preparation before use
Question and Answer IconNeed help?

Do you have a question about the Tyent Scale Remover and is the answer not in the manual?

Summary

Package Contents

Safety Precautions and Warnings

Child Safety and Usage Restrictions

Keep device out of reach of children and do not use other substances than citric acid provided.

Operational Safety Guidelines

Avoid continuous use over 30 mins, do not use on wet floors, use on flat surfaces, avoid humidity and external water spray.

Product Component Identification

How to Use the Scale Remover

Preparation Before Use

Use 1.5v alkaline batteries, install correctly, check filter fixation, and water ionizer power plug.

Usage Instructions for Desktop Model

Connecting Hoses for Desktop Model

Connect water ionizer's alkaline outlet and drain to the scale remover's respective connections.

Operation Procedure for Desktop Model

Mix citric acid, start device, allow 10 mins operation, disconnect hoses, flush ionizer.

Usage Instructions for Undersink Model

Connecting Hoses for Undersink Model

Connect ionizer's alkaline outlet/drain to scale remover, use combined hose for UCE-PLUS.

Operation Procedure for Undersink Model

Mix citric acid, start device, allow 10 mins operation, disconnect, flush ionizer.

Usage Instructions for Hybrid Model

Hybrid Model Setup and Operation

Turn on hybrid ionizer, enter setting mode, run scale cleaning, operate scale remover.

Connector Usage and Storage

Connector for Drain Hose

Instructions for connecting the scale remover inlet to the water ionizer drain hose directly.

Post-Use Cleaning and Storage

Wash inside, drain water, dry device and hoses, and store safely, ensuring filter is not lost.

Product Warranty Information

Tyent Scale Remover Specifications

General IconGeneral
BrandTyent
ModelScale Remover
CategoryUltrasonic Jewelry Cleaner
LanguageEnglish