72-0115 21 10/04/18 314 SKSM 218 A 70146
Saaku Sauna (Helo CUP)
QSG (Quick Start Guide)
Mounting Heater
See template and heater mounting instruction packed in box with heater.
Drill four 9/64" holes to fasten the heater to the wall. Install two ¼" x 1 ¹⁄ "
hex head lag screws with two washers on each screw (supplied with the
heater) into the upper two holes. Tighten these screws until their heads are
about 1/8" from the wall surface. The screws must be threaded through the
wall into a framing member or backing board to support the heater weight.
Hang the heater on the two upper screws. Locate the two ¼" x 1" hex head
lag screws (supplied with the heater) then install them into the two lower
mounting holes. Tighten to lock the heater in place.
Electrical Access:
1. Remove the bottom cover from under the heater.
2. Remove the lower right cover to access electrical connections.
Electrical Connection of Heater
The sauna heater must be connected to the supply voltage by a qualified
electrician.
Must use 90°C rated wiring with copper wire. Heater must be grounded!
Route the feed wires through the holes provided in the bottom of the heater
and connect wires under the screw terminals. See chart below for correct
wire size.
1
2 3
6
4 5
L1
L2
240V / 1 Phase
3,0 kW - 9,0 kW
1 2 3
1
2
3
1
3
L1 L1 55
B1 B2 B3
A1 A2 A3
4 5 6
1.
2.
3.
1
3
1
3
4
6
4
6
4
6
1. Power input
2. N/A
3. N/A
Heaters are dual rated for 230volt and 240volt, single phase.
Table below shows 240 volt North American Standards:
1
2
1 230 13.0 20 12-2 W/G 3.0
1 240 13.3 20 12-2 W/G 3.2
1 230 17.4 20 10-2 W/G 4.0
1 240 18.3 20 10-2 W/G 4.4
1 230 23.9 30 10-2 W/G 5.5
1 240 25.0 30 10-2 W/G 6.0
1 230 31.7 40 8-2 W/G 7.3
1 240 33.3 40 8-2 W/G 8.0
1
230
36.1 8-2 W/G 8.3
1 240 37.9 8-2 W/G 9.1
HEATER MODEL /
Product Number
50
50