TYM T1003 - DIAGNOSING AND TROUBLESHOOTING; COMPRESSOR AND MOTOR FAULT TRACING

TYM T1003
130 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Bubbles or foam visible Trouble shoot
No bubble shown
High-pressure pipe is hot
abnormally.
H-L pressure of the
pressure gauge needle
indicates high pressure
abnormally
Too much of refrigerant deflate.
High pressure pipe is not abnormal
H.L pressure of the pressure
gauge needle indicates high
abnormally.
Abnormal
Refrigerant in the
sight is shown clearly
When engine rpm
operates with high low
some bubbles disappear
slowly
Normal refrigerant gas situation
High pressure pipe is hot
Low pressure pipe is cool
High low pressure is normal
with below.
Low: 1.5~2.0kg/
High: 14.5~15kg/
Abnormal
5.Diagnosing malfunctions.
(1) Tracing faults
SYMPTOM
CONDITION
CAUSE
REMEDY
SYMPTOM
CONDITION
CAUSE
REMEDY
1.Compressor
Abnormal
sound
Inlet sound
Outlet sound
Insufficient Lub. Replenish
Belt tension release Adjust
Release the bracket
Tighten the
bolts
Clutch fail Check
Abnormal
revolution
Inlet cause
Damaged parts Check,replace
Slip the clutch Check,replace
Not Lub. Replenish
Outlet cause Belt tension released Adjust
Refrigerant or
oil leakage
Refrigerant or
oil leakage
Sealing washer
damaged
replace
Head bolt released
Tighten the
bolts
D-ring damaged Replace
Excessive
pressure
Low,High
pressure
Insufficient refrigerator Adjust
Compressor Replace
99