FAULTS CODE INDICATOR (Refer to page 46 – No.4:Troubleshooting indicator)
If System faults occur on the Tractor, the illuminated indicator the fault code by means of a system of
indicator flashes. In order to read the fault code, close attention must be paid to the number of indicator
flashes and the order in which these flashes are transmitted. In order to read the fault code, proceed as
follows:
: Pause
: Flash
Faults
code
1 Phase 2 Phase 3 Phase 4 Phase
Description
2 sec. First digit 1 sec. Second digit
11
Indicates Circuit Fault of the Lift
Arm solenoid for Raising
12
●●
Indicates Circuit Fault of the Lift
Arm solenoid for Lowering
13
●●●
Indicates Short Fault of the Lift
Solenoid for Raising/Lowering
14
●●●●
Indicates Connecting Fault of the
Exterior (raise and Lower) control
button for Raising
Indicates Connecting Fault of the
52
* Example – Interpretation of fault code number 14
1 Phase 2 Phase 3 Phase 4 Phase
Fault code composition
14
2 sec. First digit 1 sec. Second digit
●●●●
15
●●●●●
Indicates Connecting Fault of the
Exterior (raise and Lower) control
button for Lowering
16
●●●●●●
Indicate Power Supply Fault of
the Lift Arm Controller
(In short Circuit to +10V)
17
●●●●●●●
Indicate Power Supply Fault of
the Lift Arm Controller
(In short Circuit over +16V)
22
●● ●●
Indicates Position Sensor Fault
31
●●●
Indicates Left Daft Sensor Fault
32
●●● ●●
Indicates Right Daft Sensor Fault

Related product manuals