PATIENT
QUICK START GUIDE
TRIDENT
NANO HOLTER PATCH
For clinical support, please contact your medical provider.
For technical support related to your cardiac monitoring device, please call (971) 250-4237 or email
clearbeatsupport@tzmedical.com. Include your name and preferred contact method (phone, email, other),
and a support representative will respond as soon as possible.
Step 1: Skin Prep
Step 4: Place Device
Step 7: Record Event
Step 8: Remove Device
Step 9: Charging
Step 5: Check Status Step 6: Status Lights
Step 2: Open Package Step 3: Insert Device
Remove all hair from electrode site
with a razor and scrub the electrode
application sites with alcohol wipe,
or warm soapy water. Dry area
thoroughly.
Open package and remove the
electrode.
Place the electrode on the chest at
a 45° angle. The “wings” should
span between the sternum and left
nipple with the device body towards
the left shoulder. Press firmly on all
parts of the electrode.
If you feel a symptom while wearing
the monitor, hold the button for 4
seconds to record the event. The
light will blink green and an “Event
Recorded” tone will play.
Check the recording status by briefly
pressing the button. The device will
blink 5 times with the color of light
indicating the status as shown to the
right.
Eject the device by firmly pressing
the front edge near the
status/event button and slide the
device upward. Then slowly peel
the electrode from your skin.
Slide the device into the electrode,
matching the picture on the
electrode. Hold the device in place
until the green light turns off. Peel
the release liner from the electrode.
Trident Patch
Monitoring Electrode
INSTRUCTIONS FOR USE
•Prep application area by shaving hair and thoroughly cleaning
and drying skin. Do NOT use alcohol. Leave no residue.
HPR-0058
LEFT
STERNUM
LEFT NIPPLE
3.
1. 2.
Trident Patch
Monitoring Electrode
INSTRUCTIONS FOR USE
•Prep application area by shaving hair and thoroughly cleaning
and drying skin. Do NOT use alcohol. Leave no residue.
HPR-0058
LEFT
STERNUM
LEFT NIPPLE
3.
1. 2.
PUSH
Push
PUSH
PUSH
PUSH
PUSH
PUSH
PUSH
Push
PUSH
Recording Electrode has poor
connectivity
Recording is
complete
Blinks green 5 times Blinks yellow 5 times
Blinks red 5 times
Device requires
charging
Blinks green & yellow
When the device requires charging
(alternating G-Y-G-Y-G light),
remove the device from the patch
electrode and insert into the
charging dock. A solid
green light will indicate
that the device is fully
charged.
Question and Answer IconNeed help?

Do you have a question about the TZ Medical TRIDENT NANO and is the answer not in the manual?

Summary

Patient Quick Start Guide

Skin Preparation for Electrode Application

Remove hair and clean skin with alcohol or soap/water for optimal electrode adhesion.

Device Insertion and Electrode Placement

Insert the device into the electrode and place it on the chest at a 45° angle.

Checking and Understanding Device Status

Press the button to check status via lights and understand LED indicators.

Recording Events and Device Management

Record symptoms, remove the device, and charge it as needed.

Monitoring Best Practices and Precautions

Water Resistance and Showering Guidelines

Device is water-resistant; avoid direct water spray and full submersion during showers.

Electrode Site Care and LED Observation

Ensure sites are dry before application and use a mirror to view the LED.

Ensuring Proper Device Insertion and Removal

Firmly press device for seal and use tips for easier electrode removal.

Overview

The TRIDENT™ NANO HOLTER PATCH is a cardiac monitoring device designed for patient use, providing a quick start guide and important information for monitoring.

Function Description

The device is a Holter patch designed to record cardiac activity over an extended period. It captures and stores electrocardiogram (ECG) data, allowing for the detection of cardiac events and abnormalities. Patients can also manually record symptomatic events by pressing a button on the device. The system includes a patch electrode that adheres to the skin and a removable device that fits into the electrode.

Important Technical Specifications

  • Water Resistance: The device is water-resistant, not waterproof. It should not be fully submerged or exposed to excessive amounts of water or moisture. Direct spraying of water onto the sensor should be avoided.
  • LED Indicators: The device uses LED lights to indicate its status:
    • Recording: Blinks green 5 times.
    • Recording Complete: Blinks red 5 times.
    • Poor Connectivity: Blinks yellow 5 times.
    • Requires Charging: Blinks green and yellow.
    • Event Recorded: Blinks green with an audible tone.
    • Fully Charged: Solid green light on the charging dock.
  • Battery Life: The device requires charging when the green and yellow lights alternate.
  • Event Recording: Holding the button for 4 seconds records a symptomatic event.

Usage Features

Preparation (Step 1: Skin Prep)

  1. Hair Removal: Remove all hair from the electrode site using a razor.
  2. Skin Cleaning: Scrub the electrode application sites with an alcohol wipe or warm soapy water.
  3. Drying: Thoroughly dry the area.

Device Application (Steps 2-4)

  1. Open Package: Open the package and remove the electrode.
  2. Insert Device: Slide the device into the electrode, ensuring the picture on the device matches the picture on the electrode. Hold the device in place until the green light turns off.
  3. Peel Liner: Peel the release liner from the electrode.
  4. Place Device: Place the electrode on the chest at a 45° angle. The "wings" of the electrode should span between the sternum and the left nipple, with the device body pointing towards the left shoulder. Press firmly on all parts of the electrode to ensure proper adhesion.

Monitoring and Status Check (Steps 5-6)

  1. Check Status: Briefly press the button on the device to check its recording status. The device will blink 5 times, with the color indicating the status (green for recording, yellow for poor connectivity, red for recording complete, green and yellow for charging required).
  2. Observing LED: It may be difficult to observe the LED while wearing the device. For easier viewing, press the button while standing in front of a mirror.

Recording Events (Step 7)

  1. Symptom Occurrence: If a symptom is felt while wearing the monitor, hold the button for 4 seconds.
  2. Confirmation: The light will blink green, and an "Event Recorded" tone will play, confirming the event has been logged.

Water Exposure Guidelines

  • Avoid Submerging: Do not fully submerge the device.
  • Showering: While showering, face away from the shower head to avoid direct water spray onto the sensor.
  • Seal Integrity: When inserting the recorder, firmly press and hold the exposed edge of the device closest to the LED into the electrode patch until the green LED flashes and turns off. This ensures the device is properly recording and maintains a water-resistant seal.

Electrode Replacement

  • If a new electrode is needed for an extended study, recharge the device and repeat the application instructions.
  • Ensure electrode sites are completely dry and free of residue before applying new adhesive electrodes.

Device Removal (Step 8)

  1. Eject Device: Firmly press the front edge near the status/event button and slide the device upward to eject it from the electrode.
  2. Peel Electrode: Slowly peel the electrode from the skin.
  3. Adhesive Removal Aid: It is recommended to take a warm shower during removal. If available, apply mineral oil as the electrode is peeled away to loosen the adhesive.

Maintenance Features

Charging (Step 9)

  1. Charging Indication: When the device requires charging (indicated by alternating green and yellow lights), remove it from the patch electrode.
  2. Insert into Dock: Insert the device into the charging dock.
  3. Charging Status: A solid green light on the charging dock indicates that the device is fully charged.

Support

  • Clinical Support: For clinical support, contact your medical provider.
  • Technical Support: For technical support related to the cardiac monitoring device, call (971) 250-4237 or email clearbeatsupport@tzmedical.com. Include your name and preferred contact method (phone, email, or other) for a support representative to respond.

TZ Medical TRIDENT NANO Specifications

General IconGeneral
BrandTZ Medical
ModelTRIDENT NANO
CategoryMedical Equipment
LanguageEnglish