PAGE 1 OF 9 0821 IH-1784
DOUBLE SCISSOR
LIFT TABLES
1-800-295-5510
uline.com
H-1784, H-8152
TECHNICAL INFORMATION
SPECIFICATIONS H-1784 H-8152
Capacity 770 lbs.
1,760 lbs.
Height Raised 51" 59"
Height Lowered 13.8" 18.7"
Table Size 36 x 20 x 2" 48 x 24 x 2"
Total Height 30.3" 37.9"
Overall Length 42" 54"
Foot Pedal Cycles to Max. Height 46 70
Wheel Diameter 5" 6"
Weight 223 lbs. 379 lbs.
Working Volume of Oil Cylinder 310 ml 180 ml
Oil Capacity 400 ml 275 ml
1. Read all instructions carefully before operating the
lift table.
2. DO NOT overload the lift table and always operate
it within the rated load. Overloading will cause
damage to the lift table and the operator.
3. DO NOT stand or sit on the table to work.
4. DO NOT put hands or feet under the table when
lowering.
5. Apply the brakes while loading to prevent the table
from moving.
6. The load must be distributed uniformly across the
whole table.
7. DO NOT load loose or unstable loads onto the table.
8. DO NOT leave the table loaded for extended
periods of time.
9. DO NOT move the truck while lifting.
10. The table should only be used on flat solid surfaces.
11. Make sure not to overload the table when it is in
the raised position. The safety valve only works as
the table is lifted. Overloading in the raised position
may damage the table.
12. When loading and unloading goods in the raised
position, do not drag loads across the table.
This may cause offset loading and the table may
turn over.
13. When maintaining and repairing the table, the
stand bar should be used to support the fork arm in
order to prevent table from falling. There should not
be a load on table while maintaining and repairing
the table.
GENERAL INFORMATION
Para Español, vea páginas 4-6.
Pour le français, consulter les pages 7-9.

Questions and Answers

  • S
    Shelly FosterAug 11, 2025
    Why doesn't my U-Line Scissor Lifts reach full height?
    • R
      Rachel SmithAug 12, 2025
      If your U-Line Scissor Lift table does not reach its full height, there could be several reasons: 1. The steel ball of the check-valve might not be fully seating. To fix this, clean the valve opening and replace the steel ball. 2. The firing pin may not allow the steel ball to fully seat. In this case, adjust the tension rate of the steel wire connecting to the hand lever to adjust the seating of the firing pin. 3. There might be low hydraulic oil. If so, add hydraulic oil.
  • E
    Emily MillerAug 19, 2025
    What to do if U-Line Scissor Lifts table rises then descends?
    • J
      Julia RiosAug 19, 2025
      If the table of your U-Line Scissor Lift rises and then descends, it could be due to: 1. The steel ball of the check-valve not fully seating. To resolve this, clean the valve opening and replace the steel ball. 2. The firing pin not allowing the steel ball to fully seat. You can address this by adjusting the tension rate of the steel wire connecting to the hand lever to adjust the seating of the firing pin.
  • R
    Randy BlackAug 27, 2025
    How to fix oil leakage at firing pin in U-Line Scissor Lifts?
    • A
      Amanda HuntAug 27, 2025
      If you notice oil leakage at the firing pin of your U-Line Scissor Lift, it is likely that the O-ring is damaged. Replace the O-ring to resolve this issue.
  • M
    Melissa KentSep 3, 2025
    How to fix oil leakage at pump in U-Line H-1784 Scissor Lifts?
    • S
      sarah68Sep 3, 2025
      If you observe oil leakage at the pump of your U-Line Scissor Lift, the seal ring is likely damaged. You should change the seal ring.