4-2010
HHP-300
EXTRACTOR
120V
INFORMATION
&
OPERATING
INSTRUCTIONS
DO NOT OPERATE MACHINE UNTIL YOU HAVE READ
ALL SECTIONS OF THIS INSTRUCTIONS
IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY
1. Always use a defoamer when foaming occurs to prevent vacuum motor damage.
2. Keep machine from rain and snow, extremes in temperatures, and store in a
heated location. Use the machine indoors. Do not use outdoors.
3. Do not let the pump run dry.
4. Use approved chemicals only. NO SOLVENTS.
5. Wear gloves or use rags when removing quick disconnects to prevent burns.
6. Never use water above 130º F/54º C in the solution tank.
1
2
3
V
AC
P
U
M
P
CO
R
D
1
M
O
D
E
U
P
H
O
L
S
T
E
RY
C
A
R
P
E
T
56041859

Questions and Answers

  • S
    Scott AcostaAug 2, 2025
    What to do if my U.S. Products HHP-300 has no spray?
    • R
      Rhonda RamirezAug 2, 2025
      If your U.S. Products Scrubber is not spraying, several issues could be the cause. First, make sure the solution tank is full. If it is, check the spray tip for clogs and clean it if necessary. Also, verify that the pump is running and properly primed. Finally, inspect the valve on the wand to ensure it's operating correctly; repair if needed.
  • S
    Shannon AllenAug 9, 2025
    Why does my U.S. Products HHP-300 have low suction?
    • H
      Heather BarberAug 9, 2025
      Low suction in your U.S. Products Scrubber can arise from a few common issues. Check the cleaning tool and vacuum hose for any debris that might be causing a blockage and clear it. Also, ensure the drain gate is completely closed and that its seals aren't damaged; fix or replace them as needed. Finally, make sure the vacuum dome is correctly seated and undamaged; re-seat or replace if necessary.
  • C
    Cody AllenAug 14, 2025
    What to do if U.S. Products HHP-300 pump does not run?
    • B
      benjamin98Aug 14, 2025
      If the pump on your U.S. Products Scrubber isn't running, there are a few things to investigate. Start by checking the brushes in the pump motor and replace them if they are worn. Next, ensure that the pump is receiving power. Also, test the Motor Speed Control Circuit Board and potentiometer; replace if necessary.
  • P
    Paul BentleyAug 20, 2025
    What to do if U.S. Products Scrubber has low heat or no heat?
    • P
      Priscilla JohnsonAug 21, 2025
      If your U.S. Products Scrubber is producing low heat or no heat, consider these potential causes. Try spraying for shorter cycles of 12-15 seconds each. Flush the heat exchanger. Ensure you're using the correct tool and reduce the water flow. Use a standard length and diameter hose. Confirm that the heat is turned on, indicated by the green light or the bypass switch. Check the wall outlet for power, ensuring the breaker hasn't tripped. Check wiring for ‘opens’ if there is no power to the bypass switch.
  • A
    Amy HarrisAug 27, 2025
    What to do if my U.S. Products Scrubber has no suction?
    • D
      Debra HaleAug 27, 2025
      If your U.S. Products Scrubber isn't producing any suction, begin by ensuring the motor is receiving power. You should also test the electronic float, switch, vacuum motor, and vacuum circuit board, replacing any of these components if necessary.

Summary

Information and Operating Instructions

Initial Operating & Safety Warnings

Key operating precautions and warnings before initial use.

Important Safety Instructions

Electrical Hazard Warnings

Precautions to prevent electric shock and related dangers.

Safe Usage and Environment

Guidelines for safe operation, storage, and environmental conditions.

Machine Setup and Maintenance

Inspection and Cleaning Solutions

Guidance on unpacking, inspection, and chemical usage for cleaning.

Maintenance Procedures

Daily flushing, monthly maintenance, and lubrication advice.

Controls and Operation

Switch Plate Functionality

Description of the HHP-300 switch plate controls.

Circuit System Operation

Explanation of the circuit locator and bypass switch.

Operation Details

Setup and Priming Process

Step-by-step guide for filling, plugging in, and priming.

Vacuum Shutoff and Pressure

Auto vacuum shutoff mechanism and pump pressure adjustment.

Parts and Troubleshooting

Parts List

Detailed list of replacement parts for the HHP-300.

Troubleshooting and Specifications

Troubleshooting Guide

Solutions for common machine operational issues.

Product Specifications

Technical specifications and warranty summary.

U.S. Products HHP-300 Specifications

General IconGeneral
ModelHHP-300
CategoryScrubber
Power SourceBattery
Battery Voltage12 V
Flow Rate1.5 GPM
Battery TypeLead Acid