EasyManua.ls Logo

uher sg 561 royal User Manual

uher sg 561 royal
74 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
UHER
SG561
ROYAL
Betriebsanleitung
Operating Instructions
Instructions d'emploi

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the uher sg 561 royal and is the answer not in the manual?

uher sg 561 royal Specifications

General IconGeneral
Branduher
Modelsg 561 royal
CategoryRecording Equipment
LanguageEnglish

Summary

Setting Up the SG 561 ROYAL

Air Circulation

Ensuring proper ventilation for unit heat exchange.

Operating Position

Information on unit placement and wall mounting options.

Extension of Connecting Leads

Guidelines for extending connecting leads, recommending expert service.

AC Mains Connection, Operating Voltage and Mains Fuse

Details on AC mains connection, voltage selection, and fuse replacement.

Attaching the Carrying Handle

Instructions for attaching and adjusting the carrying handle for operation and transport.

Attaching and Removing the Transparent Dust Cover

Procedure for attaching and removing the transparent dust cover.

Loading the Tape

Step-by-step guide for loading magnetic tape onto the machine's spools.

Socketry

Microphone Input

Details on connecting various microphones, including necessary adapter leads.

Headphones Output

Information on connecting stereo headphones and switching built-in loudspeakers.

Phono Input

Connecting record-players and other high-impedance sources via DIN plugs.

Radio/Phono I Input/Output

Connecting tuners, receivers, and tape recorders with DIN plugs.

Remote Control Socket A

Connecting UHER remote control switches and the 'Akustomat' automatic switch.

Slide Projector Socket

Connecting to amplifiers with monitor input or automatic slide projectors.

Left Loudspeaker Output

Connecting external loudspeakers for the left channel playback.

Right Loudspeaker Output

Connecting external loudspeakers for the right channel playback.

Controls and Their Functions

MICRO Switch

Engages microphone input and disengages radio/phono input.

Separate-Channel Level Controls for MICRO and Radio/Phono I Inputs

Adjusting record levels for left and right channels of MIC/RADIO inputs.

Separate-Channel Level Controls for Phono II Input

Adjusting record levels for left and right channels of Phono II input.

Level Meter for Left Channel

Displays peak level readings for the left channel in record/playback.

Level Meter for Right Channel

Displays peak level readings for the right channel in record/playback.

MONITOR (SOURCE/TAPE) Switch

Selects monitoring mode between source and tape during recording.

MULTIPLAY/ECHO Control

Regulates record level for multiplay and echo effects.

Dual Control for Treble and Bass Adjustment

Adjusting treble and bass response for both channels during playback.

Separate-Channel Volume Controls

Adjusting playback volume for left and right channels.

RECORD Button

Engages record mode; locks when transport is in PAUSE or START.

Operating Mode Selector

Sets the machine for eleven different operating modes via function indicators.

Tape Speed Selector

Selects tape speed and switches power on; can also be used as amplifier.

Tape Transport Switch

Controls tape transport functions: STOP, PAUSE, and START.

Fast-Wind Switch for Fast-Forward and Rewind

Controls fast-forward and rewind functions, locks in end positions.

Counter with Reset Key

Resets the counter to '0000' and notes index numbers for locating passages.

Connecting the SG 561 to the Amplifier of a Hi-Fi Sound System

Connecting to an Amplifier with DIN Sockets

Connecting to hi-fi amplifiers equipped with 5-pin DIN sockets.

Connecting to an Amplifier Not Equipped with DIN Sockets

Connecting to amplifiers not equipped with DIN sockets using adapter leads.

Connecting to an Amplifier Equipped with Monitor Input

Connecting to amplifiers with monitor input and selection for source/off-tape monitoring.

Connecting to a Receiver, a Single-Unit Console or Tuner

Connecting to receivers, single-unit consoles, or tuners using Stereo Lead K 541.

Record Operation

For Users in a Hurry

Simplified procedure for quick recording, covering basic steps.

For True Audio Enthusiasts

Detailed guide for optimal recording quality, including input source connection.

Connecting Input Sources

Connecting sound equipment to appropriate sockets for recording.

Power Supply

Precautions for first-time connection and power supply, including fuse safety.

Making Record Level Test and Starting to Record

Testing and setting record levels before starting actual recording for optimal results.

Playback Operation

For Users in a Hurry

Basic procedure for playing back tapes through the machine's amplifier.

For True Audio Enthusiasts

Advanced tips for achieving optimal playback quality and monitoring.

Special Effects and Trick Recording

Mono Recording with Echo Effects

Producing reverb and echo effects in mono recordings using tape speed and controls.

Stereo Recording with Echo Effects

Achieving echo effects in stereo recordings using specific leads and controls.

Sound-on-Sound ("Synchro-Play")

Recording simultaneously on parallel tracks for effects like singing duets.

Sound-with-Sound ("Multiplay")

Creating multiple recordings by transferring tracks, enabling multi-person recordings.

"Dia-Pilot"

Procedure

Steps for synchronizing commentary and music with automatic slide projector control.

Connecting Accessory Equipment and Adjusting the SG 561 to Special Operating Conditions

Operation with UHER "Akustomat" F 411

Using the 'Akustomat' for automatic start/stop tape transport during recording.

Operation with UHER Timer A 403

Operating the SG 561 with a timer for automatic playback or recording.

Recording with UHER Telephone Adapter A 261

Connecting a telephone adapter for recording telephone conversations.

Changing UHER Tape Head Assembly Z 345 or Z 346

Procedure for changing tape head assemblies, including cover removal.

Azimuth Adjustment of Playback Head

Adjusting the playback head azimuth for optimal high-frequency reproduction.

Using UHER Reducer-Adapter K 853

Connecting the SG 561 to mono sound equipment using the reducer-adapter.

Adding Sound to Film

Synchronizing sound with film using pulse-controlled signals via the tape head.

Erasing Only

Performing tape erasure without actual recording by setting controls to minimum.

Rapid Erasure

Using a rapid erasure device for quick tape erasure during FF/REW.

Using the SG 561 as a Hi-Fi Stereo Amplifier

Care and Maintenance

Cleaning Tape-Touching Parts

User-performable cleaning of tape-touching parts like heads and guides.

Additional Technical Remarks

Contact Wiring, Input/Output Impedances, Input/Output Voltages

Detailed specifications for contact wiring, input/output impedances, and voltages.

Performance Specifications and Special Features

Summary of technical specifications, performance data, and special features.

Related product manuals