INSTALLATION MANUAL
MANUALE DI INSTALLAZIONE
MDUN 10H - MDUN 13H
MDUN 18H - MDUN 24H
INVERTER SPLIT AIR CONDITIONER
CLIMATIZZATORI D’ARIA A PARETE INVERTER
Question and Answer IconNeed help?

Do you have a question about the UnicalAir MDUN 10H and is the answer not in the manual?

UnicalAir MDUN 10H Specifications

General IconGeneral
BrandUnicalAir
ModelMDUN 10H
CategoryAir Conditioner
LanguageEnglish

Summary

Selecting the Installation Place

Indoor Unit Installation Location

Guides on where to install the indoor unit, considering wall strength, obstructions, heat sources, power, sunlight, and accessibility.

Outdoor Unit Installation Location

Guidelines for placing the outdoor unit, avoiding heat/steam, wind/dust, high traffic, and ensuring proper air discharge and sound levels.

Operating Limits

Specifies the operating temperature ranges for cooling and heating modes.

Outdoor Unit Condensed Water Drainage

Indoor Unit Installation

Wall Hook Bracket Installation

Instructions and diagrams for installing the wall hook bracket for the indoor unit, including leveling, fixing screws, and wall hole preparation.

Refrigerant Piping Connection

Indoor Unit Mounting

Indoor Unit Condensed Water Drainage

Outdoor Unit Installation

Piping Connection Details

Connecting Refrigerant Pipes

General advice on handling and connecting refrigerant pipes, avoiding damage and repeated bending.

Indoor Unit Pipe Connections

Steps for shaping connection pipes, removing caps, creating flanges, and connecting pipes to the indoor unit.

Outdoor Unit Pipe Connections

Procedures for connecting pipes to the outdoor unit, focusing on proper tightening torque to prevent leakage.

Flange Connection Tightening Torque

Table specifying tightening torque for different pipe sizes and corresponding stress levels.

Protection Caps Tightening Torque

Torque values for protection caps, crucial for sealing.

Refrigerant Leakage Inspection

Emphasizes checking for refrigerant leakage after piping connection using a leak detector.

Electrical Connections (10000-13000 BTU/h)

Indoor Unit Electrical Wiring

Steps for connecting electrical wires to the indoor unit terminals, emphasizing correct wire size and safety codes.

Outdoor Unit Electrical Wiring

Procedures for connecting electrical wires to the outdoor unit terminals, matching indoor unit numbering and securing cables.

Final Installation Stages

Indoor Unit Post-Installation Test

Checks to perform on the indoor unit after installation to ensure all functions are working correctly.

Outdoor Unit Post-Installation Test

Checks to perform on the outdoor unit to verify noise, vibration, air flow, and coolant leakage.

Electrical Connections (18000-24000 BTU/h)

Indoor Unit Electrical Wiring (18000-24000 BTU/h)

Steps for connecting electrical wires to the indoor unit terminals for 18000-24000 BTU/h models.

Outdoor Unit Electrical Wiring (18000-24000 BTU/h)

Procedures for connecting electrical wires to the outdoor unit terminals for 18000-24000 BTU/h models.

Final Installation Stages (18000-24000 BTU/h)

Indoor Unit Post-Installation Test (18000-24000 BTU/h)

Checks for indoor unit functionality after installation.

Outdoor Unit Post-Installation Test (18000-24000 BTU/h)

Checks for outdoor unit operation, noise, and leakage.