LEONARDO EVOLUTION
INSTALLATION MANUAL
LEONARDO EVOLUTION
VERSION: 1.7
DATE: FEBRUARY 2010
LANGUAGE: ENGLISH

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Uniflair LEONARDO EVOLUTION TDAV1622 and is the answer not in the manual?

Summary

Safety

General Instructions

Emphasizes adherence to European safety standards and the importance of authorized personnel for installation and repair.

Warnings for lifting and transportation

Provides safety precautions for lifting and moving units, stressing secure anchoring and keeping personnel clear of the load.

Warnings for installation

Highlights that electrical work must be done by specialists and installation must be in non-public access areas.

Safety during maintenance work

Requires maintenance to be performed by qualified personnel and emphasizes disconnecting power before starting work.

Leonardo Evolution - Direct Expansion

Delivery and Installation Checks

Covers essential checks upon delivery, installation area requirements, and unit positioning.

Refrigerant System Connections

Details refrigerant connections for air-cooled units and guidance on sizing discharge tubes.

Refrigeration Circuit Management

Evacuation and Refrigerant Charging

Details the procedures for evacuating and charging the refrigeration circuit with refrigerant.

Manual Start Up and Shut Down

Unit Start-up Procedure

Step-by-step guide for starting up the unit, including checks and user terminal operations.

Unit Shut-down Procedure

Instructions for safely turning off the unit via the user terminal.

Setting and Adjustment

Troubleshooting

Unit Start-up Issues

Addresses problems related to the unit not starting, including power supply and control panel issues.

Temperature Control Problems

Diagnoses issues causing room temperature to be too high or too low, with possible causes and corrective actions.

Refrigerant Circuit Problems

Covers issues like high/low compressor discharge/suction pressure and high-pressure switch interventions.

Compressor Problems

Addresses issues related to compressor suction pressure, operation, internal protection, and noise.

Leonardo Evolution - Chilled Water

Electrical connections

Provides instructions and warnings for safely connecting chilled water units to the electrical power supply.

Leonardo Evolution Energy Saving

Leonardo Evolution Twin-Cool

Technical characteristics

Details technical specifications for Twin-Cool units with backward curved blade fans.

Name and description of the principle components

Identifies and describes the main components of the Twin-Cool units with diagrams.

Uniflair LEONARDO EVOLUTION TDAV1622 Specifications

General IconGeneral
Energy Efficiency ClassA
RefrigerantR410A
Energy Efficiency Ratio (EER)3.2
Coefficient of Performance (COP)3.5
Power Supply400V/3Ph/50Hz
ModelLEONARDO EVOLUTION TDAV1622