Essential safety instructions, personnel requirements, and precautions during maintenance.
Safety procedures for lifting, transporting, and installing the unit.
Identifies and describes cooling circuit and heat exchanger components.
Step-by-step guide for connecting main power supply cables.
Procedure for connecting the safety valve discharge to safely vent refrigerant gas.
Guidelines for installing refrigerant connections and protecting pipes.
Guidance on selecting discharge tube diameter for proper oil flow and performance.
Charts for determining R407C discharge tube diameter based on capacity and length.
Charts for determining R410A discharge tube diameter based on capacity.
Charts to assess R410A discharge tube sizing based on equivalent length.
Charts for R410A discharge tube sizing considering pressure drop.
Example demonstrating discharge tube diameter selection for R407C.
Provides liquid line diameter recommendations and suggested condenser models.
Detailed procedures for evacuating and charging the refrigeration circuit.
Step-by-step guide for manually starting up the unit.
Instructions for safely shutting down the unit via the user terminal.
Instructions for setting differential pressure switches for air flow and filters.
Details on setting safety devices and water temperature limits.
Troubleshooting steps for unit startup and temperature control problems.
Diagnostic steps for room temperature being too low.
Diagnostic steps for humidity control and fan operation issues.
Troubleshooting for electric heater safety thermostat intervention.
Diagnosing and resolving high compressor discharge pressure problems.
Troubleshooting steps for low compressor discharge and suction pressures.
Diagnosing low suction pressure and potential coil freezing issues.
Troubleshooting for non-operational compressors, protection intervention, and noise.
Identifies key components of the chilled water units for models 2222 to 3342.
Procedures for checking unit delivery, packaging, and contents.
Step-by-step instructions for safely unloading the unit.
Critical warnings regarding electrical connection safety, voltage, and personnel.
Guide for connecting power supply cables to various unit models.
Instructions for connecting auxiliary electrical components to the terminal board.
Details for connecting unit drains and humidifier drains to the building's drainage system.
Procedure for setting the FS differential pressure switch for fan operation monitoring.
Procedure for setting the PFS differential pressure switch for monitoring dirty filters.
Schedule and checklist for regular maintenance tasks.
Identifies key components of the Twin-Cool units for models 511 to 1822.
Details the functions of the user terminal, panel door, and electrical panel components.
| Brand | Uniflair |
|---|---|
| Model | LEONARDO EVOLUTION TUAR1322A |
| Category | Air Conditioner |
| Language | English |