FIRST TIME CONTROL SETUP
SECTION B, PAGE 13
EXAMPLE: Dimension A = 24ā, and dimension B = 18ā, and the area of the air
cylinder is 19.6in
2
. These numbers would be entered as:
Press and the SOLUTIONi control will show:
If the air pressure = 50psi, then: TIP FORCE = 26.1 X 50 = 1,350 POUNDS.
It will then exit out to the next setup program.
B10. SETTING UP Automatic Voltage Compensation
(AVC). This function will maintain the RMS voltage going into the welder
transformer within a +/- 1% window for a line voltage variation of +/- 10%.
Press 5 times. The display shows:
Press and the display shows:
TIP FORCE IS
26.1 times air psi
989-ENTER VOLTAGE
to SET BASELINE for
AUTO.VOLTAGE COMP.
SELECT=YES, SKIP=NO
LINE VOLTAGE CALIB.
LINE VOLTAGE is ___
After entering data
Press YES
CYLINDER to PIVOT
Distance 24.0in
After entering data
press YES
Distance from PIVOT
to ELECTROCE = 18.0
After entering data
press YES