SECTION D, PAGE 4
D2.2 SINGLE, NO WELD, and RUN/REPEAT BUTTONS
Push =
When the foot pedal is closed, the control will do one weld sequence and open
the electrodes. It will not repeat another weld sequence even if the foot pedal
remains closed.
Push =
When the foot pedal is closed, the control mechanically go through one sequence
without passing any welding heat. It will not repeat another sequence even if the
foot pedal remains closed.
Push =
When the foot pedal is closed, the control will mechanically go through one
sequence without passing any welding heat. It will repeat this sequence if the foot
pedal remains closed with REPEAT OFF TIME (as set in the welding program
being used) between the opening of the electrodes and the next closing.
Push =
When the foot pedal is closed, the control will go through one weld sequence and
open the electrodes. It will repeat this sequence if the foot pedal remains closed
with REPEAT OFF TIME (as set in the welding program being used) between the
opening of the electrodes and the next closing.