CHANGING MODES WITH A LIGHTED FIRE
If the stoves mode of operation is to be changed while there is a fire
burning, the following procedure should be followed.
AIRTIGHT TO FIREPLACE MODE
1.Open the firedoor on the end of the stove and position the wood and
coals in towards the back and middle of the firebox. Be sure nothing is
resting against the front doors that could fall out when the doors are
opened.
2.Pull the left hand baffle to the firedoor end so the opening between the
two baffles is in the center of the stove.
3.Close the firedoor and turn the draftwheel to the closed position.
4.Wait about five minutes and open the front door slowly.
5.Reposition the fire as needed and put the spark guard in place.
FIREPLACE TO AIRTIGHT MODE
1.Remove the spark guard and close and latch the front doors.
2.Open the flue damper.
3.Open the firedoor and move the baffles to the right end of the stove. The
opening should be towards the fire door end of the stove.
4.Rake the coals towards the firedoor end of the stove and add wood as
necessary.
5.Close the firedoor and adjust the draft to the desired heat output.