Climate Co˘ntrol
Zoning System
Installation Guide
R A D I A N T H E AT I N G A N D
COOLING SYSTEMS
CLIMATE CO
˘
N T R O L
ZONING SYSTEM
INSTALLATION GUIDE

Table of Contents

Questions and Answers

  • A
    Alexander GarciaAug 20, 2025
    Why is the display off on my Uponor Control Systems thermostat?
    • M
      Mary HudsonAug 20, 2025
      If the display is off on your Uponor Control Systems thermostat, the batteries may be dead, of the wrong type, or installed incorrectly. Try replacing the batteries to resolve this issue.
  • G
    Gabriel WilliamsAug 22, 2025
    What to do if the battery icon is displayed on my Uponor Control Systems thermostat?
    • A
      Amanda KrauseAug 22, 2025
      If your Uponor Control Systems thermostat displays a battery icon, it means the thermostat batteries are getting low. Replace the batteries to resolve this issue.
  • R
    robert49Aug 25, 2025
    What to do if display in Uponor I-75 Control Systems interface locks up?
    • K
      Kevin EspinozaAug 25, 2025
      If the Uponor Control Systems interface locks up, it could be due to a general failure. Try resetting the interface to resolve the issue.
  • M
    Michael HughesAug 26, 2025
    What to do if no response or frozen interface display on Uponor Control Systems?
    • L
      Luke JohnsonAug 26, 2025
      If your Uponor Control Systems interface is unresponsive or frozen, the system may be stalled. Reset the interface; all parameters are saved, except for time and date.
  • W
    williamsalazarAug 28, 2025
    Why is the room too warm with Uponor I-75?
    • M
      Micheal ThomasAug 28, 2025
      If a room is too warm when using Uponor Control Systems, it could be due to several reasons: * The actuator may not be closing correctly – check that it is properly mounted. * The thermostat setting may be too high – adjust the temperature setpoint using the + or – keys. * A heat source might be influencing the thermostat – relocate the thermostat. * The thermostats might be mixed up – ensure each thermostat is in the correct room.
  • S
    sarah09Aug 30, 2025
    Why is the room too cold with Uponor I-75?
    • S
      Scott BarnettAug 30, 2025
      If a room is too cold when using Uponor Control Systems, it could be due to several reasons: * The thermostat setting may be too low – adjust the temperature setpoint using the + or – keys. * A heat source might be influencing the thermostat – relocate the thermostat. * The thermostats might be mixed up – ensure each thermostat is in the correct room. * The actuator may not be opening – replace the actuator.
  • J
    Jared WhitneySep 1, 2025
    How to fix poor radio reception on Uponor I-75 Control Systems?
    • B
      Brittany WaltonSep 1, 2025
      If you experience poor radio reception with your Uponor Control Systems, it could be due to several factors. The antenna may be mounted inside a metal cabinet, out of position, or disconnected, or there may be interference. Try changing the location of the antenna.
  • D
    david20Sep 3, 2025
    Why do the Power LED and channel LED blink on Uponor I-75?
    • N
      Natasha LawrenceSep 3, 2025
      If the Power LED and channel LED blink on your Uponor Control Systems, it indicates a short circuit. This might be on a connected actuator. Try using another channel if one is available. If the short circuit is on the actuator terminal or due to a wiring error, consult Section 3 for base unit replacement.
  • C
    Caleb LewisSep 5, 2025
    How to troubleshoot Uponor I-75 Control Systems that does not start?
    • J
      johnsonjoshuaSep 5, 2025
      If your Uponor Control Systems do not start, ensure the base unit is powered correctly by checking the voltage.
  • H
    Holly LongSep 7, 2025
    What to do if all connected base units are not found by the Uponor I-75 interface?
    • L
      laurathomasSep 7, 2025
      If all connected base units are not found by the Uponor Control Systems interface, there may be wiring problems. Correct the wiring to resolve this issue.

Uponor I-75 Specifications

General IconGeneral
Operating Temperature32°F to 122°F (0°C to 50°C)
DisplayLCD
Housing MaterialPlastic
Operating Voltage24 VAC
Power Supply24 V AC/DC
Storage Temperature-20 °C to +60 °C