01 0202
CR2
02
01
urbansecurity.
n
ALARM INSTRUCTIONS:
1- The owner can decide if activating or not the independant electronic module.
2- Pressing the button within 15 seconds, a short beep and the LED light will indicate that the alarm is being activated. After 10 seconds, 2 beeps will
confirm that the alarm sensor is on alert mode.
3- If the lock is attacked, 6 beeps and the led light will go on as warning function first.
4- If within the next 5 seconds the attack continues, the alarm and led light will go on for 10 seconds cycles, that will repeat if it is being attack within the
next 15 seconds.
5- After 15 seconds without detecting any attack, the alarm stops and resets to the alert mode.
6- To disconnect the alarm, open the lock with the key.
REPLACING THE BATTERY OR MODULE:
1- A strange noise or malfunction states that you probably must replace the batteries.
2- Remove the allen screws that hold the metal cover at the base of the lock.
3- With the lock open, remove the alarm module and replace the CR2 battery as photos.
KEYLOCKING:
1- Clean with multipurpose spray.
2- Grease with lithium + PTFE (teflon) spray
or synthetic + PTFE spray (as used for
chains).
WARRANTY TERMS:
1- The lock is warranted for 2 years since the purchasing ticket date.
2- The defective product has to be returned with ALL THE KEYS and the purchasing ticket.
3- The warranty is limited to the replacement of a recognized manufacturing defect, excluding the
disfuntions due to improperly use, a lack of care or an accidental cause.
U
22