USB 3001 - 3002 - 3003
Class-D Power amplifiers
TWO AMPLIFIERS LINKED TO ONE CHANNEL
TROUBLESHOOTING
RUN indicator doesn t light up
check all fuses on the amplifier
check main fuse near the battery
check plus and minus battery cables
check remote voltage
Bass response is low
one speaker cable could be disconnected
the bass control on the r
adio is set on low
an active crossover unit is adjusted wrong
© US Blaster Europe BV
RUN indicator is on but no sound
check volume control on the radio
check GAIN regulator on the amplifier
check RCA cables and connections
check speaker cables and connections
The amplifier switches on and off
cable terminals and battery terminals are oxidized
low voltage from the battery
remote wire is connected wrong
bad chassis ground connection with amplifier