Operation and
Maintenance
Manual
for
M SERIES - 2000
Reverse Osmosis Systems
For Dialysis Applications
Serial # ________________________
8/97 MANOWNROSM REV F-
Question and Answer IconNeed help?

Do you have a question about the US Filter M SERIES - 2000 and is the answer not in the manual?

US Filter M SERIES - 2000 Specifications

General IconGeneral
BrandUS Filter
ModelM SERIES - 2000
CategoryWater Filtration Systems
LanguageEnglish

Summary

INDICATIONS

CAUTIONS AND WARNINGS

Provides crucial safety information, warnings, and cautions for operating and servicing the system.

2.0 SYSTEM INSTALLATION

2.1 PRECAUTIONS BEFORE INSTALLATION

Lists critical feedwater source requirements and precautions before commencing installation.

2.4 POWER REQUIREMENTS

Details the electrical power requirements and connection procedures for the RO system.

2.5 WATER REQUIREMENTS

Specifies the necessary inlet water supply requirements for optimal system performance.

2.9 BEFORE POWER TURN ON

Crucial pre-power-on checks and warnings to prevent damage and ensure safety.

2.10 INSTALLATION OF REVERSE OSMOSIS MEMBRANE(S)

Step-by-step guide for installing the RO membranes into the system housing.

3.0 OPERATING INSTRUCTIONS

3.2 INITIAL STARTUP OF REVERSE OSMOSIS SYSTEM

Step-by-step guide for safely starting up the RO system for the first time.

3.4 NORMAL OPERATIONS

Instructions for running the RO system under normal operating conditions.

4.0 SYSTEM MAINTENANCE

4.2 SANITIZING THE REVERSE OSMOSIS MEMBRANE(S)

Details the importance and procedures for sanitizing RO membranes to maintain performance.

E. Cleaning the System

Addresses system cleaning due to membrane fouling and factors affecting performance.

5.0 TROUBLESHOOTING

5.1 SYSTEM INOPERATIVE

Steps to diagnose and resolve issues when the system is not functioning.

5.2 LOW SYSTEM PRESSURE

Guides on troubleshooting low pressure conditions, including pump and prefilter checks.

5.7 SYSTEM KEEPS SHUTTING OFF

Identifies causes for system shutdowns, such as overload relays, sensors, or controller issues.

5.8 SYSTEM SHUTOFF, LOW PRESSURE

Troubleshooting system shutdowns related to low pressure, checking prefilters and switches.

5.9 SYSTEM SHUTOFF, HIGH TEMPERATURE

Addresses system shutdowns due to high temperature, checking permeate flow and thermistor.

5.10 LOW PERMEATE FLOW RATE

Resolves issues with low permeate flow rate, including pressure, piping, and membrane fouling.