EasyManua.ls Logo

UWANT M300 - User Manual

UWANT M300
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Question and Answer IconNeed help?

Do you have a question about the UWANT M300 and is the answer not in the manual?

Overview

The UWANT M300 is a mattress vacuum cleaner designed for cleaning and removing mites from various textiles such as mattresses, blankets, pillows, and sofas. This product manual provides essential information for safe operation, maintenance, and troubleshooting.

Function Description:

The UWANT M300 is an electric appliance primarily used for deep cleaning and mite removal from fabric surfaces. It incorporates several key functions to achieve this:

  • Vacuuming: It effectively suctions dust, dirt, and mites from textiles.
  • UV Sterilization: Equipped with a UV lamp, the device provides sterilization to kill bacteria and mites. The UV lamp operates within a specific range (within 3cm of the irradiated object and an inclination angle not exceeding 30°) and automatically turns off outside this range to prevent injury.
  • Vibrating Function: The device includes a vibrating feature, likely to agitate dust and mites from deep within the fabric for more effective removal.
  • Supersonic Function: This feature suggests the use of high-frequency sound waves, which can further aid in dislodging mites and dust.
  • Drying Function: The "Dry" indicator on the display panel suggests a function to dry the cleaned surface, possibly through airflow, to prevent moisture buildup.
  • Aroma Ball Installation: The device allows for the installation of an aroma ball, which can release a pleasant scent during or after cleaning.

Important Technical Specifications:

  • Model: M300
  • Power Supply: 220-240V~, 50/60Hz
  • Rated Power: 500W
  • Dust Collection Volume: 500ml
  • Main Motor: 220V, 350W
  • Roller Brush Motor: Included for brush operation.

Usage Features:

  • Simple Operation: To use, place the mite remover on the bed, connect to the power supply, press the power switch, and gently push it back and forth to clean.
  • No Forceful Operation Required: The device is designed to be simply placed on the bed and pushed; no need to lift or hold it down forcefully.
  • UV Lamp Safety Mechanism: The UV lamp automatically turns off if lifted more than 1cm from the surface or if the inclination angle exceeds 30°, preventing direct exposure to UV rays. Users are advised not to look at the bottom of the machine when the UV lamp is on and to avoid irradiating plants or concentrating UV rays in one place for continuous use.
  • Initial Use Odor: It is normal for some odors to be discharged from the air outlet during first use; these are harmless and will dissipate naturally.
  • Cleaning Frequency Recommendation: Initially, it is recommended to use the mite remover 2-3 times a week, reducing to once a week thereafter.
  • Aroma Ball Replacement: The device features an aroma ball installation place. To replace, pull off the silicone plug, remove the old aroma ball, insert a new one, and replace the silicone plug.
  • Display Screen Panel: The device has a display screen panel with indicators for Sterilization, Supersonic, Dry, and Vibrating functions, allowing users to monitor the active cleaning modes.
  • Power Switch and Display: A power switch is provided for easy operation, and a display shows the current status.

Maintenance Features:

  • Dust Cup Cleaning:
    • After use, press the dust cup release button to remove the dust cup.
    • Press a designated button on the dust cup to take it out and empty the garbage.
    • Pull out the cyclone assembly from the dust cup.
    • Take out the filter sponge.
    • The filter sponge can be washed with water, but it must be completely dried before reuse.
    • After cleaning, dry and put back the filter sponge.
    • Assemble the dust cup after the parts are dry.
    • It is recommended to clean the dust cup and filter sponge after each use. If the dust cup is full, it should be cleaned immediately.
    • Do not scrub the filter sponge violently when cleaning.
    • The filter sponge should be replaced after approximately 30-50 hours of cumulative use to maintain performance.
  • Brush Cleaning and Disassembly:
    • Turn off the machine and unplug the power.
    • Move the button on the roller brush cover to both sides to make the roller brush cover pop up.
    • Remove the roller brush cover and the roller brush assembly.
    • To reinstall, align the hooks of the roller brush cover with the holes of the machine body, and then press the roller brush cover until it clicks into place.
    • Warning: Disconnect power before cleaning the roller brush to avoid accidental activation and injury.
  • UV Lamp Cleaning:
    • Wipe the transparent cover of the UV lamp to ensure the best sterilization effect.
    • Do not look directly at the germicidal lamp or let it irradiate the skin.
  • Troubleshooting Guide: The manual includes a comprehensive troubleshooting section for common issues such as the machine not working, reduced suction force, UV lamp not working, machine stopping suddenly, or roller brush stopping. It provides possible causes and treatment methods, including cleaning blockages, ensuring proper placement, and contacting after-sales service for damaged components.
  • Storage: When not in use for a long time, store the machine in a cool and dry place, away from direct sunlight and moisture.
  • Environmental Responsibility: The product has an "Environment friendly use period of 10 years," indicating that hazardous substances will not leak or mutate under normal use. It also features an arrow recycling symbol, advising users to hand it over to a formal recycling channel for disposal of waste electrical and electronic products when it exceeds its service period or fails.

UWANT M300 Specifications

General IconGeneral
BrandUWANT
ModelM300
CategoryVacuum Cleaner
LanguageEnglish

Related product manuals