What does AC overvoltage mean on V-TAC VT-6605105?
- CCrystal LopezAug 19, 2025
AC overvoltage on your V-TAC Inverter suggests a high voltage from the public grid is present.
What does AC overvoltage mean on V-TAC VT-6605105?
AC overvoltage on your V-TAC Inverter suggests a high voltage from the public grid is present.
What does AC undervoltage mean on V-TAC VT-6605105 Inverter?
AC undervoltage on your V-TAC Inverter means that there is a low voltage of the public grid.
What to do if the public grid disconnects from my V-TAC VT-6605105?
If the public grid disconnects from your V-TAC Inverter, check if the inverter AC connection is well.
What does 'Input undervoltage' mean on my V-TAC VT-6605105?
An 'Input undervoltage' message on your V-TAC Inverter indicates PV1 undervoltage or PV2 undervoltage.
What does 'Bus undervoltage' mean on my V-TAC VT-6605105 Inverter?
If your V-TAC Inverter displays 'Bus undervoltage', it indicates a DC input problem.
What does AC underfrequency mean on V-TAC VT-6605105 Inverter?
AC underfrequency on your V-TAC Inverter indicates a low frequency of the public grid.
Why is my V-TAC VT-6605105 showing a 'Clock alarm'?
If your V-TAC Inverter shows a 'Clock alarm', it means there is a wrong setting.
What does 'Manual shutdown' mean on my V-TAC VT-6605105?
A 'Manual shutdown' message on your V-TAC Inverter indicates that the operation was stopped by the operation panel or upper PC.
What does 'Internal communication fault' mean on my V-TAC VT-6605105 Inverter?
An 'Internal communication fault' on your V-TAC Inverter indicates that the master-slave DSP communication is disabled or there is an error of master-slave DSP check bit.
What does 'Data consistency fault' mean on my V-TAC VT-6605105 Inverter?
A 'Data consistency fault' on your V-TAC Inverter indicates inconsistent grid voltage, frequency, leakage current or AC/DC injection.
Outlines essential safety measures for inverter installation and operation to prevent hazards.
Detailed safety instructions covering installation, operation, and maintenance for user protection.
Instructions for safe delivery, unpacking, and physical installation of the solar inverter.
How to operate the inverter when connected to the public electricity grid.
Procedures for regular checks and maintenance to ensure inverter performance and longevity.
Steps for safely unpacking and checking the inverter and its accessories upon arrival.
Step-by-step instructions for mounting the inverter using the provided bracket and hardware.
Safety warnings and regulations for electrical wiring connections in the PV system.
Detailed instructions for making secure DC connections using the specified connectors.
Steps for safely connecting the inverter to the AC power grid.
Critical checks required before powering on and operating the inverter.
The process for starting and configuring the inverter for grid synchronization.
Recommended frequency and methods for performing periodic maintenance on the inverter.
Methods for accessing and displaying real-time operational data and performance metrics.
Reviewing past faults and understanding their root causes and meanings.
Explains fault codes, their messages, and potential causes for troubleshooting.
| Model | VT-6605105 |
|---|---|
| Category | Inverter |
| Output Voltage | 220-240V AC |
| Protection Features | Overload, Overheat, Short Circuit, Low Voltage, High Voltage |
| Output Frequency | 50Hz |
| Efficiency | Up to 90% |
| Cooling | Fan |