PROBLEM
REASONS REMEDY
No display in
LCD
Power cord is not
plugged in well.
Problem from the power
supply.
The over Temperature
Protection device is not
working.
The fuse is not working
Plug in, turn on the machine.
Check if the other Machines work
normally.
Cut o electricity and reconnect it after
it is cool down.
Take the machine to be repaired by a
specialist
Water temperature
does not increase
Set temperature below
or close to the water
temperature.
Set heating time is too
short
Check the setting.
Prolong the heating time.
Water goes
on heating
after the set
temperature
is reached.
Temperature sensor is
invalid.
The circulator does not
rotate.
Take the machine to be repaired by a
specialist
E01
Low water
Check if the water level is lower than
the MIN water line.
Check and ensure the filter is not stuck.
Check if the water level switch
and relative circuit is OK (require
technicians to check and repair).
E02
The temperature could
not reach a required
temperature in a certain
time.
Check if the lid is closed
Check and ensure the filter is not stuck.
If the machine was filled with new cool
water during heating.
Check if the pump works normally.
Check if the heater works normally.
Check if the temperature probe works
normally.