TECHNICAL DETAILS
Mains Water supply inlet 1” BSP Female Thread
Pump Connection 1” BSP Female Thread
Water Outlet Connection 1” BSP Female Thread
Protective Rating IP44
Min Mains Pressure 100 kPa
Max Mains Pressure 1000 kPa
Water Temp Range 1°C - 40°C
Ambient Temp Range 1°C - 40°C
Rated Supply Voltage 230 - 240Vac
Max Electrical Load 10A
Power Consumption (Mains) 1W
Power Consumption (Tank) 18W
Minimum Flow Rate 2 L/min
PRODUCT OVERVIEW / APPLICATION
The Vada Rain2Main is designed to select between stored rainwater
(when available) and mains supply water, and send this water to
your toilet cistern, washing machine, garden and other non-potable
household water applications. It features automatic pump control to
minimise the use of electricity while saving water.
When your tank is empty, the Rain2Main seamlessly switches to
mains water supply so that there is no interruption of water to your
toilet cistern or washing machine.
Do not use the Rain2Main for liquids other than clean water.
WARRANTY & AFTER SALES SERVICE
You have purchased a quality product from Reece Australia. This
product is covered by a 24 month warranty. This warranty covers faults
in the product construction, material and assembly. Faulty products
will be repaired or exchanged free of charge. Faulty items become our
property.
This warranty does not include faults caused by
• Unsuitable or improper use
• Incorrect installation
• Normal wear and tear
• Inadequate or complete lack of maintenance
• Chemical, electrochemical or electrical influences
To the maximum extent permitted by law, Reece excludes all warranties
other than those set out above. In the event of a warranty claim, we
will replace or repair defective products, or pay for the cost of having
defective products repaired or replaced, but will not be liable for any
injury to any person, damage to any property, any indirect or
consequential loss, or in any other respect.
For after sales service, call 1800 080 055.
VADA - Rain2Main Automatic Rainwater Controller
INSTALLATION INSTRUCTIONS
• The operator must be provided with this owner’s manual. This
must be read before instlalation and followed during installation.
• These instructions are a guide only. Users not familiar with the
installation and maintenance of electrical and pumping equipment
should seek advice from people with experience in pump installa-
tion and operation.
Rain2Main is designed to be used with clean water in a
residential application. Do not use with alternative fluids,
specifically abrasive, corrosive or explosive fluids.
This appliacne is not intended for use by persons (incl children)
with reduced physical, sensory or mental capabilities, or lack of
experience or knowledge, unless have been given supervision
or instruction concerning the use of the appliance. Children
should be supervised to ensure they do not play with Rain2Main.

Questions and Answers

Summary

Product Overview and Application

Technical Details

Installation Instructions

Warranty and After Sales Service

Installation

Preparation for Installation

Read instructions, inspect for damage, and manage mains pressure.

Fittings and Accessories

Ensures all required fittings and accessories are ready before installation.

Protection

Warranty void if not operated per manual; house unit in weather-proof enclosure.

Installation Recommendations

Guidance on filter insertion, tank outlet height, pipe distance, and water quality.

Mounting

Details on mounting the pump and Rain2Main on a solid, level, vibration-free surface.

Installation

Connecting to Pump

Step-by-step guide for connecting the Rain2Main to the pump using the union kit.

Mains Inlet Connection

Connecting the incoming mains water supply to the Rain2Main inlet.

Water Outlet Connection

Connecting household plumbing to the Rain2Main outlet for water distribution.

Pipe Marking

Requirements for marking pipes and outlets connected to the Rain2Main system.

Electrical Connection

Guidance on safe electrical connections, RCD use, and wiring requirements.

Operation

Commissioning

Steps for initial setup, priming the pump, and testing the system's functionality.

Mains Supply Mode

How the system operates and switches to mains water when rain water is unavailable.

General Operation

Automatic operation, behavior during power outages, and manual override functions.

Service and Maintenance

General Precautions

Ensuring a vermin-free environment and isolating power before service.

Service Procedure

Steps for safely removing the unit for servicing, including valve closure.

Resetting from Loss of Prime

Procedure to reset the unit after a loss of prime condition.

Troubleshooting Guide

No Water Delivery

Diagnosing and resolving issues when no water is being delivered from the pump.

No Water from Mains Supply

Troubleshooting when the system defaults to mains supply but no water is delivered.

No Water Supply At All

Identifying causes and solutions for a complete lack of water supply.

Poor Water Pressure

Addressing issues related to low water pressure through the pump.

Pump Continually Runs

Resolving problems where the pump runs continuously without stopping.