What to do if there is no or insufficient exhaust air or supply air in my Vaillant recoVAIR VAR 360/4 E?
- MMaria CarterNov 26, 2025
If you're experiencing no or insufficient exhaust or supply air, several factors could be the cause. First, check if the filters are dirty and clean them if necessary. Ensure that neither the exhaust-air nor the supply-air lines are blocked, and clean them if they are. Verify the fan's functionality and replace it if defective. Make sure the airflow isn't too low, and if it is, install an intake grille with increased airflow. Also, check that the supply-air and exhaust-air valves aren't closed too far; open them and adjust the system accordingly. If the supply-air temperature is too low, wait until it increases; normal operation should resume when the supply air temperature is above 10°C. If the outside temperature is too low, check whether S.812 is displayed in the Live Monitor and wait u...