14 Operating and installation instructions 0020200905_02
Setting level Values Unit Increment, select Default
setting
Min. Max.
Time programmes → ZONE1: Heating →
Individual days and
blocks
Monday, Tues-
day, Wednesday,
Thursday, Friday,
Saturday, Sunday
and Monday - Fri-
day, Saturday -
Sunday, Monday -
Sunday
Mo - Fr:
06:00-
22:00
Sa: 07:30-
23:30
Su: 07:30-
22:00
Period 1: Start – End
Period 2: Start – End
Period 3: Start – End
00:00 24:00 h:min 00:10
Time programmes → ZONE1: Cooling →
Individual days and
blocks
Monday, Tues-
day, Wednesday,
Thursday, Friday,
Saturday, Sunday
and Monday - Fri-
day, Saturday -
Sunday, Monday -
Sunday
Mo - Fr:
06:00-
22:00
Sa: 07:30-
23:30
Su: 07:30-
22:00
Period 1: Start – End
Period 2: Start – End
Period 3: Start – End
00:00 24:00 h:min 00:10
Days away from home scheduling →
Start 01.01.01 31.12.99 dd.mm.yy Day.Month.Year 01.01.14
End 01.01.01 31.12.99 dd.mm.yy Day.Month.Year 01.01.14
Temperature 5 30 ℃ 1 15
Days at home scheduling →
Start 01.01.01 31.12.99 dd.mm.yy Day.Month.Year 01.01.14
End 01.01.01 31.12.99 dd.mm.yy Day.Month.Year 01.01.14
Basic settings → Language →
Selectable language English
Basic settings → Display →
Display contrast 1 15 1 9
Button lock off, On Off
Preferred display Heating, Cooling Heating
Basic settings → Offset →
Room temperature -3.0 3.0 K 0.5 0.0