Do you have a question about the Vaillant VWL 75/5 AS and is the answer not in the manual?
Heating Capacity | 7.5 kW |
---|---|
Energy efficiency class | A++ |
Refrigerant | R410A |
Sound Power Level | 61 dB(A) |
Power Input Cooling | 1.5 kW |
Type | Air Source Heat Pump |
Power Supply | 230 V, 50 Hz |
EER Cooling | 4.0 |
Classification and types of action-related warnings using signal words.
Defines the product's intended domestic use and allowed combinations.
Covers risks related to operation, product changes, and qualifications.
Identifies and describes the product's control elements and their functions.
Detailed explanation of the control panel display, symbols, and buttons.
Explains the meaning of various symbols displayed on the control panel.
Describes the function of soft keys and other buttons on the control panel.
Lists and describes various safety devices integrated into the product.
Describes the default display showing current status and daily energy yield.
How to display and check the filling pressure in the heat pump circuit.
Procedure to prevent low water pressure and add water if needed.
Final checks for system function and leak-tightness before handing over to the user.
Guidance on setting cylinder temperature, with warnings about Legionella risk.
Procedure to check and maintain correct filling pressure in the heat pump circuit.
Procedure for checking heating installation pressure daily and annually.
How fault messages appear, their priority, and limp-home mode functionality.
Guidance on using a table to check and resolve problems.
Warnings and procedures for safe disposal of refrigerant due to environmental risk.
Warnings and procedures for safe disposal of refrigerant due to environmental risk.
Guidance on checking and treating heating water quality.
Steps for filling and purging the heating installation, including leak checks.
Instructions on powering up the system, including the installation assistant.
Guidance on using the installation assistant for initial product setup.
How to enable and set the electric back-up heater output.
Instructions for setting the anti-legionella function, requiring back-up heater activation.
How the installation assistant configures the heating installation and allows parameter adjustment.
Procedure to set flow temperature in heating mode without connected control.
How to view product operating modes and status codes via the Live Monitor.
How fault codes are displayed, their priority, and how to eliminate them.
How to access and view the last ten recorded faults.
Procedure to clear the fault memory.
Procedure to reset all product parameters to factory default.
Information on the product's safety cut-out and troubleshooting steps.
How to check and adjust the heating installation's filling pressure.
List of fault codes, their causes, and remedies for troubleshooting.