Wireless Magnet Contact (EN)
Kabelloser Magnetkontakt (DE)
Contact aimant sans fil (FR)
Contacto magnético inalámbrico (ES)
Contatto magnetico via radio (IT)
Contacto magnético sem fios (PT)
Trådløs magnetkontakt (NO)
Draadloos magneetcontact (NL)
Bezdrátový magnetický kontakt (CZ)
Trådlös magnetkontakt (SV)
Edition: 04.04.2016
CADIM: A5Q00053228
P/N 7121727 Rev. A
English Installation Instruction
Before starting to install and work with this device, please read the Safety
Instructions
Scope of delivery (fig.1):
IMKW6-10 Wireless Magnet Contact + battery 3.6V ½ AA (a)
Magnet unit (b)
Screws: for detector (c), for magnet (d)
Plugs (e)
Jumper: for disabling the back tamper switch
Installation
Removing the front cover (Fig. 2-3)
Insert a screwdriver in the slot of the snap release and push gently, until the
front cover is disengaged and you hear the opening click (Fig. 2).
Lift the Printed Circuit Board (Fig. 3b).
Mounting the base (Fig. 4)
Pay attention to the guidelines in the Installer Manual for mounting the
IMKW6-10.
Break out the desired holes on the base for proper installation.
Mount the base to a fixed part of a door or window.
Install the Printed Circuit board back into the base.
Use only the screws and plugs supplied.
Setting operation Mode (external contacts)
The unit can be configured for connecting one or more external contacts (NC) in
series. This connection is protected by End Of Line 8.2k Ohm series resistor. The
external wiring can be up to 15 m (certified up to 3 m).
There are 3 operation modes for the IMKW6-10. The unit learns the mode of
operation during power-up (insertion of the battery).
Disable back tamper switch
The back tamper of the unit can be deactivated by inserting a jumper (Fig.
3a).
When the bypass jumper is set, the unit complies with EN50131 security
grade 1. When the jumper is NOT set, the unit complies with EN50131
security grade 2.
Mounting the magnet (Fig. 5)
Mount the magnet on the moveable part of a door or window, aligned
with the markings on the base of the detector.
Installing the battery (Fig. 6-7)
Risk of explosion if battery is replaced by an incorrect type. Use only
batteries delivered by the supplier.
Insert the battery according polarity (-) (+) (Fig. 6).
Place the cover by inserting back in the appropriate closing pin.
Screw in the retaining screw (Fig. 7).
Enrolment
To enrol the IMKW6-10 on the SiWay panel/gateway, please follow the
instructions of the corresponding installation/configuration manual.
Testing
Alarm transmission test
Select the “Walk Test Mode” in the control panel as described in the
installation/configuration manual in order to avoid a real alarm
transmission.
Remove the magnet:
The control panel will indicate each alarm transmission received.
Replace the magnet:
The alarm message disappears.
Maintenance and Service
Check the detector regularly (at least once a year) to ensure that it is
functioning correctly (by carrying out a walk test), that it is free of dirt, and
that it is securely attached. If necessary, clean and /or secure the detector.
up to 300 m at open space
Unique ID serial number – 24 bit
Alarm, Tamper, Supervision,
Internal Reed Switch and External contacts
Open/close distances (Fig.
5a)
* Not tested by Telefication
Lithium. 3.6 V Type: XL-050F, Size: 1/2AA
Environmental conditions:
< 85% r.h., non condensing
Housing protection EN60529,
EN50102
EC Declaration of Conformity
Hereby, Vanderbilt International (IRL) Ltd declares that this radio equipment type is in
compliance with all relevant EU Directives for CE marking. From 20/04/2016 it is in
compliance with Directive 2014/30/EU (Electromagnetic Compatibility Directive) and
Directive 2014/35/EU (Low Voltage Directive). From 13/06/2016 it is also in
compliance with Directive 2014/53/EU (Radio Equipment Directive).
The full text of the EU declaration of conformity is available at:
http://pcd.vanderbiltindustries.com/doc/wireless
EN 50130-4:2011, EN 50130-5: 2011, EN 50131-2-6:2008,
EN 50131-5-3:2005+A1:2008 and R&TTE
EN 61000-6-3:207/A1:11;
EN 301 489-1 V1.9.2; EN 301 489-3 V1.6.1
EN 300 220-2 V2.4.1
EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013.
EN 62479.
EN50131-2-6, Security Grade 2, Environmental Class II certified by:
For more detailed instruction please refer to the manuals of the respective control panel or