V&P Scientific, Inc. 1 Technical Note 329A
Technical Note 329A
OPERATION MANUAL FOR
VP 710C5 SERIES
ALLIGATOR TUMBLE STIRRERS
*US Patent # 6,176,609
WARNING!!!!!
Be advised that the Magnetic Tumble Stirrer has very strong magnetic fields coming
from a 48 MGO Neodymium Iron Boron drive magnet.
People with pacemakers should not get closer than 24 inches.
Remove all magnetic influenced tools and objects from the immediate area to prevent
them from being pulled onto the magnet or from striking anyone as the objects are
pulled towards the magnet.
Keep credit cards, watches, and other magnetic sensitive items at least 24 inches from
the Magnetic Tumble Stirrer’s magnetic fields.
Do not operate the Magnetic Tumble Stirrer in the close proximity to large pieces of
aluminum or ferromagnetic material. For more information see TUMBLE STIRRER
INSTALLATION section.
Control
Unit
Tumble
Stirrer
Question and Answer IconNeed help?

Do you have a question about the V&P Scientific VP 710C5 Series and is the answer not in the manual?

Summary

Safety Warnings and Precautions

Magnetic Field Hazards

Strong magnetic fields from the stirrer require precautions for pacemakers and magnetic-sensitive items.

Tumble Stirrer Installation

Material Proximity Guidelines

Avoid operating near ferromagnetic or aluminum materials to prevent drag, heat, and motor strain.

Tumble Stirrer Operation

Connecting Control Unit and Stirrer

Instructions for connecting the control unit to the Tumble Stirrer using the provided cable.

Operating Controls and Speed

Details on the ON/OFF switch, speed control knob, RPM display, and speed limitations.

Product Maintenance and Specifications

Optimal Stir Speed Factors

Factors influencing optimal stir speed, including application, container, liquid properties, and stir element.

General Product Care

Guidelines for product care: power off when not in use, humidity/temperature tolerance, and cleaning the deck.

Additional Stirrer Specifications

Equipment rating for voltage, amperage, and frequency, and ambient environment requirements.

Safety Precautions and Assistance

Hazard Reduction and Liability

Reducing hazards through proper use and V&P Scientific's disclaimer for customer failure to comply.

Technical Assistance Contact

Information for obtaining technical assistance via phone or email.

Warranty Information

Product Warranty Terms

Details on the one-year warranty for defects, repair/replacement policy, and exclusions for user negligence.

Overview

The V&P Scientific, Inc. VP 710C5 Series Alligator Tumble Stirrer is a laboratory instrument designed for efficient and controlled stirring of various materials. Its primary function is to create a tumbling motion, which is particularly effective for applications such as stirring microbial cultures, resolubilizing extracts, and stirring in deep well microplates. The device utilizes a powerful magnetic field generated by a 48 MGO Neodymium Iron Boron drive magnet to achieve this stirring action.

Technical Specifications:

  • Model Series: VP 710C5
  • US Patent: # 6,176,609
  • Drive Magnet: 48 MGO Neodymium Iron Boron
  • Maximum Speed (No Load): 1500 RPM
  • Recommended Speed (with substantial magnetic resistance/aluminum): No more than 750 RPM
  • Typical Tumble Stirring Applications Speed: 300 – 500 RPM
  • Motor Type: Powerful servo motor
  • Equipment Rating: 115/230V~, 1.6A, 60/50 Hz
  • Ambient Humidity: 0-95% (non-condensing)
  • Ambient Temperature: 0-70°C
  • Deck Material: ABS

Usage Features:

The Tumble Stirrer system consists of two main components: a Control Unit and the Tumble Stirrer itself.

  • Control Unit: This unit houses the power supply, an ON/OFF power switch, a speed control knob, and an LCD display with an RPM meter. It also includes connection ports for the power cable and the stirrer connection cable, as well as a USB port (for factory purposes).
  • Speed Control: The speed control knob allows users to precisely adjust the stirring speed. The LCD display provides a true RPM reading, enabling accurate monitoring of the stirring process. The controller is programmed to compensate for magnetic resistance by increasing power to maintain the set RPM.
  • Connection: The Tumble Stirrer connects to the Control Unit via a connection cable (two plugs, one blue and one black) that transfers power. The power cord connects the Control Unit to an appropriate power outlet.
  • Application Versatility: The device is suitable for a wide range of applications, from low-speed stirring of microbial cultures to high-speed stirring for resolubilizing extracts or in deep well microplates. The optimal operating speed is application-dependent and should be empirically determined.
  • Safety Features: The Tumble Stirrer is equipped with a safety mechanism that turns the unit off if the motor temperature exceeds 135°C, preventing damage from overheating.

Maintenance Features:

  • General Care: When not in use, the power switch should be turned off.
  • Cleaning: The deck of the Tumble Stirrer, made of ABS, can be cleaned using a mild detergent and then wiped dry. It is crucial not to submerge any part of the Tumble Stirrer into liquids.
  • Motor Longevity: The powerful servo motor is designed for high torque and long-term stirring applications. However, repeated overheating can reduce product longevity. If the unit turns off due to overheating, the power supply should be turned off, and the motor allowed to cool before restarting. Operating speed parameters should be modified to prevent future overheating.

Important Safety Precautions:

Due to the very strong magnetic fields generated by the 48 MGO Neodymium Iron Boron drive magnet:

  • Pacemakers: Individuals with pacemakers must maintain a distance of at least 24 inches from the device.
  • Magnetic Objects: All magnetic-influenced tools and objects should be removed from the immediate area to prevent them from being pulled onto the magnet or striking anyone.
  • Sensitive Items: Credit cards, watches, and other magnetic-sensitive items should be kept at least 24 inches away from the Magnetic Tumble Stirrer's magnetic fields.
  • Proximity to Materials: Operating the Magnetic Tumble Stirrer in close proximity to large pieces of aluminum or ferromagnetic material is not recommended. Ferromagnetic materials will cause significant magnetic resistance, while large/thick aluminum structures will cause drag due to eddy currents, leading to increased strain on the motor and potential overheating. If operating near these materials is unavoidable, test run parameters without supervision and modify operating speeds to prevent overheating.

V&P Scientific, Inc. assumes no liability for the customer's failure to comply with safety requirements and practices. The product comes with a one-year warranty covering defects in material and workmanship under normal laboratory conditions, starting from the date of delivery. Damage caused by user negligence is not covered. Customers are advised to keep the special shipping carton for potential returns.

V&P Scientific VP 710C5 Series Specifications

General IconGeneral
BrandV&P Scientific
ModelVP 710C5 Series
CategoryLaboratory Equipment
LanguageEnglish