What to do if nothing works on my vanEE 90H-V ECM HRV?
- CChristian RiveraJul 27, 2025
First, check if the unit is properly plugged in. Next, verify if the unit is receiving power from the house circuit breaker or fuse.
What to do if nothing works on my vanEE 90H-V ECM HRV?
First, check if the unit is properly plugged in. Next, verify if the unit is receiving power from the house circuit breaker or fuse.
Why is there condensation on windows with my vanEE 90H-V ECM HRV Test Equipment?
If you notice condensation on the windows, it means the air is too humid. To fix this: * Operate the unit on maximum speed ventilation until the situation is corrected. * Leave curtains half-open to allow air circulation. * Store all firewood in a closed room with a dehumidifier or in a well ventilated room, or store the wood outdoors. * Do not adjust the thermostat of your heating system below 18°C (64°F).
What does it mean if the LED of the integrated control is blinking AMBER on my vanEE 90H-V ECM HRV?
If the LED is blinking amber, there is a problem with the motorized damper and the unit is OFF. For a 2½-hour period, the unit will try to reset the damper at every 30 minutes. After 2½ hours, if the problem is not solved, the unit stops trying to reset damper.
What to do if air is too cold at the air supply grille of my vanEE 90H-V ECM HRV?
If the air is too cold at the air supply grille: * Check if the exterior hood is blocked. * Operate the unit in low speed ventilation, in intermittent or in recirculation mode (if available). * Install a duct heater.
What to do if inside air is too dry with my vanEE 90H-V ECM HRV?
If the inside air is too dry: * Temporarily use a humidifier. * Operate the unit in recirculation mode (if available).
What does it mean if the LED of the integrated control is blinking RED on my vanEE 90H-V ECM HRV?
If the LED is blinking red, it indicates a problem with one of the motors and the unit is OFF.
What does it mean if the LED of the integrated control is blinking GREEN on my vanEE 90H-V ECM HRV?
If the LED is blinking green, there is a problem with the thermistor. The unit is still working, but will defrost frequently.
Type | Heat Recovery Ventilator (HRV) |
---|---|
Airflow @ 0.4 in. w.g. | 68 CFM |
Apparent Sensible Effectiveness @ -25C | 60% |
Voltage | 120V |
Power Consumption | 27 Watts |
Details the unit's 30-second startup sequence and LED indicators for HRV/ERV and 90H-V+/60H-V+ models.
Describes the integrated control button and LED indicators for unit status (speed, off).
Explains the use of optional external controls and their interaction with the integrated control.
Step-by-step guide for performing quarterly maintenance, including filter cleaning.
Steps for annual maintenance, including cleaning unit walls and recovery core.